Pressure Raising Time and Rate from a Saturation Temperature Ramp

Saturation temperatures at two pressures (IF97), the time to raise pressure at an allowed temperature ramp, and dp/dT at the start.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolIAPWS-IF97 (water and steam)Boiler

Inputs

Examples: 2 to 46 bar(a) at 100 °C/hCold start 1 to 67 bar(a) at 60 °C/h

Results

A constant temperature ramp means slow pressure rise at first and fast later: pressure per kelvin grows with pressure.

Saturation temperature at start120.21°C
Saturation temperature at end258.78°C
Time to raise pressure1.3857h
Pressure rise per kelvin at the start (kPa per K)6.3261kPa

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 2 to 46 bar(a) at 100 °C/h. The inputs, in the units selected above:

InputValue
Starting pressure (absolute)2.0000 bar
Final pressure (absolute)46.000 bar
Allowed saturation temperature ramp100.00 °C/h

Applying the formula below gives:

ResultValue
Saturation temperature at start120.21 °C
Saturation temperature at end258.78 °C
Time to raise pressure1.3857 h
Pressure rise per kelvin at the start (kPa per K)6.3261 kPa

Open this example in the calculator and change any input.

Formula

\(t = \frac{T_{sat}(p_2) - T_{sat}(p_1)}{\dot T}, \quad \frac{dp}{dT}\Big|_{p_1}\)

Variables

Symbol Meaning SI unit
\(p_1\) Starting pressure (absolute) Pa
\(p_2\) Final pressure (absolute) Pa
\(\dot T\) Allowed saturation temperature ramp K/s
\(T_{sat,1}\) Saturation temperature at start K
\(T_{sat,2}\) Saturation temperature at end K
\(t\) Time to raise pressure s
\(dp/dT\) Pressure rise per kelvin at the start Pa/K

Method and standards

IAPWS-IF97 saturation line: saturation temperatures at the two pressures, the time as their difference over the ramp, and dp/dT at the start by a central difference of the saturation pressure over ±0.01 K.

Where it is used

  • Start-up procedures.
  • Operator training.

Common mistakes

  • Gauge pressures.

Assumptions and limits

  • Uniform ramp.
  • The ramp limit is on metal temperature; the drum and header metal lags the saturation temperature during a fast rise, so following the saturation ramp exactly is slightly non-conservative. Use the maker's start-up curve.

References

  • Saturation temperature and pressure from IAPWS-IF97; dp/dT by central difference

Questions and answers

Why ramp on temperature, not pressure?

Thermal stress follows metal temperature, which follows saturation temperature.

Why is low-pressure raising slow in pressure terms?

Near atmospheric pressure, each kelvin adds only a few kPa.

Allowed ramp?

From the boiler maker's start-up curve for drum and header thickness.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.