FireCADCalc

Attemperator Outlet Temperature for a Spray Flow

Steam temperature after an attemperator or desuperheater for a given spray water flow, with the remaining superheat, by an enthalpy balance (IAPWS-IF97).

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationPulp and paperFood, dairy and textileIAPWS-IF97 (water and steam)BoilerDesuperheater and PRDS

Inputs

Examples: 50 t/h at 66 bar(a) / 520 °C, 2 t/h spray at 150 °C20 t/h at 45 bar(a) / 450 °C, 1 t/h at 105 °CPRDS outlet: 10 t/h at 4 bar(a) / 350 °C, 0.8 t/h at 105 °C

Results

Steam temperature out251.61°C
Superheat remaining107.99K
Steam flow out10,800kg/h
Steam enthalpy out2,967.9kJ/kg

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 50 t/h at 66 bar(a) / 520 °C, 2 t/h spray at 150 °C. The inputs, in the units selected above:

InputValue
Steam flow in50,000 kg/h
Steam pressure (absolute)66.000 bar
Steam temperature in520.00 °C
Spray water flow2,000.0 kg/h
Spray water pressure (absolute)90.000 bar
Spray water temperature150.00 °C

Applying the formula below gives:

ResultValue
Steam temperature out474.91 °C
Superheat remaining193.03 K
Steam flow out52,000 kg/h
Steam enthalpy out3,355.2 kJ/kg

Open this example in the calculator and change any input.

Formula

\(h_2 = \frac{\dot m_s h_s + \dot m_w h_w}{\dot m_s + \dot m_w} \qquad T_2 = T(p, h_2) \qquad \Delta T_{sh} = T_2 - T_{sat}(p)\)

Variables

Symbol Meaning SI unit
\(\dot m_s\) steam flow in kg/s
\(p\) steam pressure Pa
\(T_s\) steam temperature in K
\(\dot m_w\) spray water flow kg/s
\(p_w\) spray water pressure Pa
\(T_w\) spray water temperature K
\(T_2\) steam temperature out K
\(\Delta T_{sh}\) superheat remaining K
\(\dot m_2\) steam flow out kg/s
\(h_2\) outlet enthalpy J/kg
\(h_s, h_w\) steam and water enthalpies (IF97) J/kg

Method and standards

Adiabatic mixing at the steam pressure with enthalpies and the outlet state from FireCAD's IAPWS-IF97.

Where it is used

  • Checking attemperator control range.
  • Investigating steam temperature excursions.
  • PRDS outlet temperatures.

Common mistakes

  • Spraying close to saturation.
  • Forgetting the spray adds to the steam flow.
  • Using spray water pressure below steam pressure.

Assumptions and limits

  • Complete evaporation and mixing; no heat loss. The spray water enthalpy at its own pressure is unchanged through the valve and nozzle (isenthalpic throttling), so the balance is on enthalpy at the steam pressure.
  • If the outlet is wet, the temperature shown is the saturation temperature and a warning gives the outlet dryness.
  • The 10 K superheat warning is a FireCAD rule-of-thumb margin, not a code value.
  • Above the critical pressure (220.64 bar) there is no saturation temperature, so the superheat is not shown.

References

  • IAPWS R7-97 IF97
  • adiabatic mixing

Questions and answers

What temperature does a spray give?

50 t/h of steam at 66 bar(a) and 520 °C with 2 t/h of 150 °C spray water leaves at 475 °C, with 193 K of superheat left.

How is this different from the spray-water calculator?

That one finds the spray for a target temperature; this one finds the temperature a spray flow gives, which is what you see when the valve sticks or is set by hand.

Why keep superheat after the spray?

Water droplets must evaporate before the next bend or the turbine; a margin above saturation makes sure they do.

Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.