FireCADCalc

Air in Steam: Partial Pressure and Temperature Drop (Dalton)

Saturation temperature of steam containing air from the steam's partial pressure (Dalton's law, IF97) and the temperature lost against pure steam.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolIAPWS-IF97 (water and steam)Desuperheater and PRDS

Inputs

Examples: 3 bar(a), 10 % air1 bar(a), 25 % air

Results

Air also collects as a film on heating surfaces, cutting heat transfer far more than the temperature drop alone: vent it.

Steam partial pressure0.75000bar
Saturation temperature of pure steam99.606°C
Temperature of the steam–air mixture91.758°C
Temperature drop7.8481K

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 3 bar(a), 10 % air. The inputs, in the units selected above:

InputValue
Total pressure (absolute)3.0000 bar
Air by volume (mole fraction) in the steam10.000 %

Applying the formula below gives:

ResultValue
Steam partial pressure2.7000 bar
Saturation temperature of pure steam133.53 °C
Temperature of the steam–air mixture129.97 °C
Temperature drop3.5575 K

Open this example in the calculator and change any input.

Formula

\(p_s = p(1 - y_a), \quad T = T_{sat}(p_s), \quad \Delta T = T_{sat}(p) - T\)

Variables

Symbol Meaning SI unit
\(p\) Total pressure (absolute) Pa
\(y_a\) Air by volume in the steam -
\(p_s\) Steam partial pressure Pa
\(T_{sat}(p)\) Saturation temperature of pure steam K
\(T\) Temperature of the steam–air mixture K
\(\Delta T\) Temperature drop K

Method and standards

Dalton's law.

Where it is used

  • Steam system troubleshooting.
  • Air vent justification.

Common mistakes

  • Air share by mass used as by volume.

Assumptions and limits

  • Saturated, well-mixed steam–air mixture: the result is for the bulk composition. Near a condensing surface air accumulates, so the local air share and temperature drop can be much larger.
  • The air share is by volume (mole fraction); a mass share entered by mistake understates the drop.

References

  • Dalton's law of partial pressures; saturation temperature from IAPWS-IF97

Questions and answers

Why does air lower the temperature?

The gauge reads total pressure, but steam condenses at its own partial pressure.

How much?

Try 10 % air at 3 bar(a): the mixture is several degrees colder than pure steam.

Cure?

Air vents at the far ends of mains and on heat exchangers, especially at start-up.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.