FireCADCalc

Condenser Air In-Leakage from a Vacuum Rate-of-Rise Test

Air leaking into an isolated condenser or vacuum system from the rate of pressure rise, the system volume and temperature (ideal gas).

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolCondenser and cooling tower

Inputs

Examples: 120 m3, 2 kPa in 10 minSmall condenser

Results

Rate of rise is shown per minute. Vapour flashing from a hot hotwell also raises the pressure; test with the hotwell cooled or allow for it.

Rate of rise (pressure per minute)0.20000kPa
Air in-leakage16.020kg/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 120 m3, 2 kPa in 10 min. The inputs, in the units selected above:

InputValue
Steam-space volume under vacuum120.00 m³
Pressure rise during the test2.0000 kPa
Test duration10.000 min
Gas temperature in the condenser40.000 °C

Applying the formula below gives:

ResultValue
Rate of rise (pressure per minute)0.20000 kPa
Air in-leakage16.020 kg/h

Open this example in the calculator and change any input.

Formula

\(\dot m_a = \frac{V}{R T}M\frac{\Delta p}{\Delta t}\)

Variables

Symbol Meaning SI unit
\(V\) Steam-space volume under vacuum m³
\(\Delta p\) Pressure rise during the test Pa
\(\Delta t\) Test duration s
\(T\) Gas temperature in the condenser K
\(\dot p\) Rate of rise, pressure per minute Pa/min
\(M\) molar mass of dry air, 28.96 kg/kmol
\(R\) universal gas constant, 8314.46 J/(kmol·K)
\(\dot m_a\) Air in-leakage kg/s

Method and standards

Ideal-gas law: the air entering an isolated volume raises its pressure at the rate \(\Delta p/\Delta t\). Plant and condenser maker practice sets the acceptance limit; no test code value is reproduced here.

Where it is used

  • Condenser performance tests.
  • Leak hunting.

Common mistakes

  • Volume of tubes and shell side confused.

Assumptions and limits

  • All the pressure rise is attributed to dry air. The water-vapour partial pressure also changes with temperature during the test and vapour flashes from a hot hotwell; neither is corrected, so the leakage may be overstated. Test with the hotwell and shell temperature steady.

References

  • Ideal-gas law applied to a vacuum rate-of-rise test; dry-air molar mass from the US Standard Atmosphere composition

Questions and answers

Why does air leakage matter?

Air blankets condenser tubes and raises back pressure, costing turbine power.

Typical limit?

Plant and maker practice give a rate in kPa per minute or kg/h per MW; compare with yours.

Where does air enter?

Gland seals, flanges, valve stems, rupture discs and low-pressure heater drains.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.