Worked example
Example: 120 m3, 2 kPa in 10 min. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Steam-space volume under vacuum | 120.00 m³ |
| Pressure rise during the test | 2.0000 kPa |
| Test duration | 10.000 min |
| Gas temperature in the condenser | 40.000 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Rate of rise (pressure per minute) | 0.20000 kPa |
| Air in-leakage | 16.020 kg/h |
Open this example in the calculator and change any input.
Formula
\(\dot m_a = \frac{V}{R T}M\frac{\Delta p}{\Delta t}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(V\) | Steam-space volume under vacuum | m³ |
| \(\Delta p\) | Pressure rise during the test | Pa |
| \(\Delta t\) | Test duration | s |
| \(T\) | Gas temperature in the condenser | K |
| \(\dot p\) | Rate of rise, pressure per minute | Pa/min |
| \(M\) | molar mass of dry air, 28.96 | kg/kmol |
| \(R\) | universal gas constant, 8314.46 | J/(kmol·K) |
| \(\dot m_a\) | Air in-leakage | kg/s |
Method and standards
Ideal-gas law: the air entering an isolated volume raises its pressure at the rate \(\Delta p/\Delta t\). Plant and condenser maker practice sets the acceptance limit; no test code value is reproduced here.
Where it is used
- Condenser performance tests.
- Leak hunting.
Common mistakes
- Volume of tubes and shell side confused.
Assumptions and limits
- All the pressure rise is attributed to dry air. The water-vapour partial pressure also changes with temperature during the test and vapour flashes from a hot hotwell; neither is corrected, so the leakage may be overstated. Test with the hotwell and shell temperature steady.
References
- Ideal-gas law applied to a vacuum rate-of-rise test; dry-air molar mass from the US Standard Atmosphere composition
Questions and answers
Why does air leakage matter?
Air blankets condenser tubes and raises back pressure, costing turbine power.
Typical limit?
Plant and maker practice give a rate in kPa per minute or kg/h per MW; compare with yours.
Where does air enter?
Gland seals, flanges, valve stems, rupture discs and low-pressure heater drains.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.