Condenser Back Pressure at Other Cooling Water Conditions

Condenser pressure at a new cooling water temperature, flow, load and tube plugging, scaled from a design point with U varying with water velocity.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolRefinery and petrochemicalChemical and fertiliserIAPWS-IF97 (water and steam)

Inputs

Examples: Cooling water 4 K warmer80 % flow, 10 % tubes pluggedPart load 70 %, winter water 20 °C

Results

U scales as water velocity^n (n about 0.5 for the water film share of resistance); fouling and air are taken as at design. Use the turbine's correction curves to turn the pressure change into output.

New saturation temperature46.665°C
New condenser pressure10.446kPa
New CW outlet42.000°C
New NTU1.1454
UA ratio1.0000

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Cooling water 4 K warmer. The inputs, in the units selected above:

InputValue
Design heat load116.00 MW
Design CW inlet28.000 °C
Design CW outlet38.000 °C
Design condenser pressure (absolute)8.5000 kPa
New heat load116.00 MW
New CW inlet32.000 °C
CW flow ratio100.00 %
Share of tubes plugged0 %
Exponent of water velocity in U0.50000 -

Applying the formula below gives:

ResultValue
New saturation temperature46.665 °C
New condenser pressure10.446 kPa
New CW outlet42.000 °C
New NTU1.1454
UA ratio1.0000

Open this example in the calculator and change any input.

Formula

Design point: \(\dot m_{w,d}c_p = \dfrac{Q_d}{t_{2,d} - t_{1,d}}\), \(NTU_d = \ln\dfrac{T_{s,d} - t_{1,d}}{T_{s,d} - t_{2,d}}\), \(UA_d = NTU_d\,\dot m_{w,d}c_p\), with \(T_{s,d} = T_{sat}(p_d)\) and \(t_2 = t_1 + Q/(\dot m_w c_p)\).

\(T_s = t_1 + \frac{Q}{\dot m_wc_p(1 - e^{-NTU})}, \quad NTU = \frac{UA}{\dot m_wc_p}, \quad \frac{UA}{UA_d} = (1 - f_{pl})\left(\frac{\dot m/\dot m_d}{1 - f_{pl}}\right)^n\)

Variables

Symbol Meaning SI unit
\(Q_d\) Design heat load W
\(t_{1,d}\) Design CW inlet K
\(t_{2,d}\) Design CW outlet K
\(p_d\) Design condenser pressure (absolute) Pa
\(Q\) New heat load W
\(t_1\) New CW inlet K
\(\dot m/\dot m_d\) CW flow ratio -
\(f_{pl}\) Share of tubes plugged -
\(n\) Exponent of water velocity in U -
\(T_s\) New saturation temperature K
\(p_c\) New condenser pressure Pa
\(t_2\) New CW outlet K
\(NTU\) New NTU -
\(UA/UA_d\) UA ratio -
\(\dot m_w c_p\), \(\dot m_{w,d}c_p\) cooling water heat capacity rate, new and design W/K
\(UA\), \(UA_d\) overall conductance, new and design W/K
\(NTU_d\) design NTU -
\(T_{s,d}\) design saturation temperature K

Method and standards

Effectiveness–NTU model of a condenser (condensing side at one temperature), with \(UA\) back-calculated from the design point and scaled with the water velocity. Scaling the whole \(UA\) by velocity to the power \(n\) is a FireCAD simplification: \(n\) about 0.5 stands for the water film being part of the total resistance. It is not the HEI correction method.

Where it is used

  • Summer–winter back pressure estimates.
  • Effect of cooling tower or tube plugging on output.

Common mistakes

  • Using the design load at part load.
  • Forgetting air in-leakage effects.

Assumptions and limits

  • Clean as at design; single pressure shell.
  • Water specific heat and the effect of cooling water inlet temperature on \(U\) (which HEI corrects for) are not modelled; at colder water the true \(U\) is lower.

References

  • Effectiveness–NTU for a condenser (C_r = 0) scaled from a design point; IAPWS-IF97 saturation

Questions and answers

Why does a warmer cooling water raise back pressure so much?

The saturation temperature must rise by about the same amount; each kelvin is about 0.39 kPa near 40 °C and 0.47 kPa near 45 °C.

What does plugging do?

It removes surface but raises water velocity in the remaining tubes, partly recovering U; the net UA falls about as √(1 − plugged share).

What do the defaults give?

The 8.5 kPa(a) design condenser with cooling water 4 K warmer runs at about 10.4 kPa(a).

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.