Worked example
Example: 8.5 kPa(a), 28 → 38 °C, 10,000 t/h, 3,000 m². The inputs, in the units selected above:
| Input | Value |
|---|---|
| Condenser pressure (absolute) | 8.5000 kPa |
| Cooling water inlet | 28.000 °C |
| Cooling water outlet | 38.000 °C |
| Condensate (hotwell) temperature | 41.500 °C |
| Cooling water flow | 10,000 t/h |
| Condenser surface area | 3,000.0 m² |
Applying the formula below gives:
| Result | Value |
|---|---|
| Saturation temperature | 42.665 °C |
| Terminal temperature difference | 4.6645 K |
| Initial temperature difference | 14.665 K |
| Condensate subcooling | 1.1645 K |
| Duty | 116.28 MW |
| LMTD | 8.7302 K |
| Overall coefficient | 4,439.7 W/(m²·K) |
Open this example in the calculator and change any input.
Formula
\(TTD = T_s - t_2, \quad ITD = T_s - t_1, \quad Q = \dot m_wc_p(t_2 - t_1), \quad \Delta T_{lm} = \frac{t_2 - t_1}{\ln\frac{T_s - t_1}{T_s - t_2}}, \quad U = \frac{Q}{A\,\Delta T_{lm}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(p_c\) | Condenser pressure (absolute) | Pa |
| \(t_1\) | Cooling water inlet | K |
| \(t_2\) | Cooling water outlet | K |
| \(T_c\) | Condensate (hotwell) temperature | K |
| \(\dot m_w\) | Cooling water flow | kg/s |
| \(A\) | Condenser surface area | m² |
| \(T_s\) | Saturation temperature | K |
| \(TTD\) | Terminal temperature difference | K |
| \(ITD\) | Initial temperature difference | K |
| \(\Delta T_{sub}\) | Condensate subcooling | K |
| \(Q\) | Duty | W |
| \(\Delta T_{lm}\) | LMTD | K |
| \(U\) | Overall coefficient, on the outside tube area | W/(m²·K) |
| \(c_p\) | specific heat of water, 4186 | J/(kg·K) |
Method and standards
Heat and mass balance definitions; condensing side at saturation.
Where it is used
- Condenser performance monitoring.
- Deciding on tube cleaning.
Common mistakes
- Using gauge vacuum instead of absolute pressure.
- Reading CW outlet temperature downstream of a bypass.
Assumptions and limits
- Steady load; c_p of water 4.186 kJ/(kg·K) (about 0.2 % above the IF97 value at 30–40 °C).
- The area must be the outside tube surface the condenser maker quotes.
References
- Babcock & Wilcox
- Steam: Its Generation and Use
- 41st ed. (2005)
- ch. 21 (condenser performance)
- Saturation from IAPWS-IF97
Questions and answers
What is TTD?
Saturation temperature at the condenser pressure minus the cooling water outlet temperature; 2.5–5 K is typical. A rising TTD at the same load means fouling or air.
Why watch subcooling?
Condensate colder than saturation wastes heat and carries more dissolved oxygen; it usually means air blanketing.
What do the defaults give?
8.5 kPa(a) (42.7 °C), water 28 → 38 °C at 10,000 t/h: TTD 4.7 K, 116 MW, U about 4,400 W/(m²·K).
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.