Worked example
Example: 25 MW duty, U 3000 W/(m²·K), 0.1 bar(a), CW 32 to 41 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Condenser heat load | 25.000 MW |
| Overall heat transfer coefficient (clean × cleanliness) | 3,000.0 W/(m²·K) |
| Condenser pressure (absolute) | 10.000 kPa |
| Cooling water inlet temperature | 32.000 °C |
| Cooling water outlet temperature | 41.000 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Tube surface area (on the basis of U, usually outside) | 976.88 m² |
| Log mean temperature difference | 8.5306 K |
| Terminal temperature difference | 4.8075 K |
| Initial temperature difference | 13.808 K |
| Saturation temperature | 45.808 °C |
Open this example in the calculator and change any input.
Formula
\(LMTD = \frac{T_{cw,2} - T_{cw,1}}{\ln\left(ITD/TTD\right)} \qquad ITD = T_{sat} - T_{cw,1} \qquad TTD = T_{sat} - T_{cw,2} \qquad A = \frac{\dot Q}{U \cdot LMTD} \qquad T_{sat} = T_{sat}(p_c)\ \text{(IAPWS-IF97)}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot Q\) | condenser heat load | W |
| \(U\) | overall heat transfer coefficient | W/(m²·K) |
| \(p_c\) | condenser pressure, absolute | Pa |
| \(T_{cw,1}\) | cooling water inlet temperature | K |
| \(T_{cw,2}\) | cooling water outlet temperature | K |
| \(A\) | tube surface area | m² |
| \(LMTD\) | log mean temperature difference | K |
| \(TTD\) | terminal temperature difference | K |
| \(ITD\) | initial temperature difference | K |
| \(T_{sat}\) | saturation temperature at \(p_c\) | K |
Method and standards
LMTD method with the steam side at constant saturation temperature (FireCAD IAPWS-IF97); U entered by you.
Where it is used
- First sizing of surface condensers for turbines.
- Checking whether an existing condenser can take a higher load.
- Back-calculating U from plant data to track fouling (with the heat load and LMTD from readings).
Common mistakes
- Using a clean-tube U without a cleanliness factor.
- Taking inside instead of outside tube area as the basis of U.
- Ignoring the air-cooling zone, which transfers heat poorly.
Assumptions and limits
- Uniform U; steam at saturation over the whole surface; no subcooling zone.
- The area is on the same basis as U: the outside tube surface, as HEI uses, when U is referred to the outside.
- The heat load is entered directly and not checked against the cooling water flow and range; use the condenser heat load calculator for that.
References
- IAPWS R7-97(2012) IF97
- LMTD method for a condensing stream
Questions and answers
How do I size a condenser?
Divide the heat load by U times the LMTD. 25 MW at 0.1 bar(a) (45.8 °C) with cooling water from 32 to 41 °C has an LMTD of 8.5 K; with U = 3000 W/(m²·K) the condenser needs 977 m².
Where does U come from?
From the HEI standard's method, the tube maker or plant data; it depends on tube material and gauge, water velocity, water temperature and a cleanliness factor. This calculator takes it as an input.
Why is the LMTD simple for a condenser?
The steam side stays at saturation temperature, so flow arrangement does not matter: LMTD = range / ln(ITD/TTD).
Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.