Burner Swirl Number from Vane Angle

Swirl number of an annular axial-vane swirler from the vane angle and the hub and outer diameters (Beér and Chigier), to judge recirculation and flame stability.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolRefinery and petrochemicalBurner and furnace

Inputs

Examples: 45° vanes60° vanes, small hub

Measured from the burner axis: 0° gives no swirl. An angle measured from the radial direction must be converted (90° minus it).

Results

Swirl above about 0.6 (the strong-swirl threshold of Beér and Chigier) forms a central recirculation zone that stabilises the flame.

Swirl number1.1707

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 45° vanes. The inputs, in the units selected above:

InputValue
Vane angle (from the burner axis)45.000 °
Hub diameter100.00 mm
Outer diameter300.00 mm

Applying the formula below gives:

ResultValue
Swirl number0.72222

Open this example in the calculator and change any input.

Formula

\(S = \frac{2}{3}\,\frac{1 - (d_h/d)^3}{1 - (d_h/d)^2}\tan\theta\)

Variables

Symbol Meaning SI unit
\(\theta\) Vane angle rad
\(d_h\) Hub diameter m
\(d\) Outer diameter m
\(S\) Swirl number -

Method and standards

Beér and Chigier, Combustion Aerodynamics: the flat-vane swirl number of an annular axial swirler, with about 0.6 as the threshold of strong swirl and central recirculation.

Where it is used

  • Burner design and retrofits.
  • Flame shape problems.

Common mistakes

  • Angle measured from the radial direction.

Assumptions and limits

  • Thin flat vanes; vane angle from the burner axis. Real vanes have thickness and the flow does not follow them exactly, so the actual swirl is lower than the flat-vane value; no correction is applied.

References

  • Beér and Chigier
  • Combustion Aerodynamics: S = (2/3)[1 − (d_h/d)³]/[1 − (d_h/d)²] tan θ for flat axial vanes

Questions and answers

Why swirl?

It creates a recirculation zone that brings hot gas back to ignite the incoming fuel.

Strong swirl threshold?

About 0.6, above which central recirculation appears.

Too much swirl?

Short wide flames that can impinge on walls and raise NOx.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.