FireCADCalc

Mill Drive: Steam Turbine vs Electric Motor Steam

Steam for a mill or shredder drive by a single-stage turbine, and by an electric drive fed from the turbo-generator, and the steam the electric drive saves.

Sugar mill and cogenerationSteam turbine

Inputs

Examples: 1 MW mill driveShredder 2.5 MW

Hugot ch. 16: double-wheel mill turbines at 22 kg/cm², 350 °C exhausting at 1.5 kg/cm² (plant steam pressures, normally gauge) use 10–15 kg steam per metric hp·h, about 14–20 kg/kWh, worse at part load.

Results

The comparison is in steam mass only: the mill turbine's exhaust goes to process, while the turbo-generator may condense part of its steam, so the saving is real only if the process does not need the extra exhaust.

Steam, turbine drive16.000t/h
Steam, electric drive (through the TG)7.2222t/h
Steam saved by the electric drive8.7778t/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 1 MW mill drive. The inputs, in the units selected above:

InputValue
Drive shaft power1,000.0 kW
Mill turbine specific steam (incl. gearing)16.000 kg/kWh
Turbo-generator specific steam6.5000 kg/kWh
Electric drive efficiency (motor, VFD, gearbox, cables)90.000 %

Applying the formula below gives:

ResultValue
Steam, turbine drive16.000 t/h
Steam, electric drive (through the TG)7.2222 t/h
Steam saved by the electric drive8.7778 t/h

Open this example in the calculator and change any input.

Formula

\(\dot m_T = P\,SR_m, \quad \dot m_E = \frac{P}{\eta_e} SR_g\)

Variables

Symbol Meaning SI unit
\(P\) Drive shaft power W
\(SR_m\) Mill turbine specific steam (incl. gearing) kg/J
\(SR_g\) Turbo-generator specific steam kg/J
\(\eta_e\) Electric drive efficiency (motor, VFD, gearbox, cables) -
\(\dot m_T\) Steam, turbine drive kg/s
\(\dot m_E\) Steam, electric drive (through the TG) kg/s
\(\Delta \dot m\) Steam saved by the electric drive kg/s

Method and standards

Definitions.

Where it is used

  • Electrification projects.
  • Cogeneration studies.

Common mistakes

  • Specific steam at the turbine, not the mill shaft.

Assumptions and limits

  • Steady load. Steam is compared by mass only; it is not a fuel or energy balance.
  • Hugot quotes the steam pressures in kg/cm² without saying gauge or absolute; for plant steam they are normally gauge readings.

References

  • Steam = power × specific steam consumption; electric drive through the turbo-generator

Questions and answers

Why electrify mill drives?

Small single-stage turbines use much more steam per kWh than a large TG.

When is the saving lost?

When process needs the exhaust the mill turbines used to supply.

Specific steam of a mill turbine?

Typically 14–20 kg/kWh at the shaft; take the maker's or test figure.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.