Electric Mill Drive Sizing

Motor rating and electrical input for a mill from the power at the rollers, gearing and drive efficiencies and Hugot's 15 % margin, with energy per tonne cane.

Sugar mill and cogenerationElectric motor

Inputs

Examples: 200 kW mill, individual driveCombined drive

The default 0.94 is an assumed figure for an enclosed planetary or helical reducer; use the maker's. Hugot: 0.78–0.79 with open pinions.
Hugot: thyristor d.c. drive about 0.90.
Hugot: 1.15 for individual drives, 1.10 for combined drives.

Results

E_c is worked out from the mean maximum power, so it is an upper bound on the energy used. Hugot's figure of about 2.7 kWh per tonne cane per mill for thyristor-controlled d.c. drives is an average consumption and comes out lower. Mills need constant torque down to about half speed.

Motor shaft power212.77kW
Motor rating244.68kW
Electrical input236.41kW
Electrical energy per tonne cane at the mean maximum load (upper bound)2.3641kWh/t

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 200 kW mill, individual drive. The inputs, in the units selected above:

InputValue
Mean maximum power at the rollers200.00 kW
Gearing efficiency (motor to rollers)94.000 %
Drive efficiency (motor and converter)90.000 %
Margin over the mean maximum1.1500 -
Crushing rate100.00 t/h

Applying the formula below gives:

ResultValue
Motor shaft power212.77 kW
Motor rating244.68 kW
Electrical input236.41 kW
Electrical energy per tonne cane at the mean maximum load (upper bound)2.3641 kWh/t

Open this example in the calculator and change any input.

Formula

\(P_m = \frac{P}{\rho}, \quad P_n = k\,P_m, \quad P_e = \frac{P_m}{\eta}, \quad E_c = \frac{P_e}{A}\)

Variables

Symbol Meaning SI unit
\(P\) Mean maximum power at the rollers W
\(\rho\) Gearing efficiency (motor to rollers) -
\(\eta\) Drive efficiency (motor and converter) -
\(k\) Margin over the mean maximum -
\(A\) Crushing rate kg/s
\(P_m\) Motor shaft power W
\(P_n\) Motor rating W
\(P_e\) Electrical input W
\(E_c\) Electrical energy per tonne cane J/kg

Method and standards

Power chain from rollers to the supply.

Where it is used

  • Specifying mill motors and drives.
  • Estimating mill electrical energy.

Common mistakes

  • Sizing on the mean power instead of the mean maximum.
  • Forgetting gearing losses.

Assumptions and limits

  • Steady mean maximum load: the energy per tonne cane is therefore an upper bound, not the average consumption.
  • The default gearing efficiency 0.94 is an assumed figure for an enclosed reducer; open pinions give about 0.78–0.79 (Hugot).

References

  • Hugot
  • Handbook of Cane Sugar Engineering
  • 3rd ed. (Elsevier, 1986)
  • ch. 14 (installed power, p. 239) and ch. 15 (electric drives, pp. 241–248)

Questions and answers

Why 15 % above the mean maximum?

Hugot's rule for individual drives covers short overloads from thick blankets; combined drives share peaks and need 10 %.

Why does speed range matter?

Mills run at constant torque over a range of about 50–100 % of speed; the drive must deliver full torque at low speed.

What about turbines?

Compare steam by turbine and by electric drive with the mill turbine calculator.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.