Worked example
Example: Typical tandem. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Mixed juice % cane (net, after the drit correction) | 105.00 % |
| Pol % mixed juice | 12.500 % |
| Bagasse % cane | 29.000 % |
| Pol % bagasse | 1.8000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Pol in mixed juice % cane | 13.125 % |
| Pol in bagasse % cane | 0.52200 % |
| Pol % cane (by balance) | 13.647 % |
| Mill extraction (pol in juice / pol in cane) | 96.175 % |
Open this example in the calculator and change any input.
Formula
\(Pol_c = Pol_{MJ}\,MJ + Pol_B\,B, \quad ME = \frac{Pol_{MJ}\,MJ}{Pol_c}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(MJ\) | Mixed juice % cane | - |
| \(Pol_{MJ}\) | Pol % mixed juice | - |
| \(B\) | Bagasse % cane | - |
| \(Pol_{B}\) | Pol % bagasse | - |
| \(Pol_{MJ,c}\) | Pol in mixed juice % cane | - |
| \(Pol_{B,c}\) | Pol in bagasse % cane | - |
| \(Pol_c\) | Pol % cane | - |
| \(ME\) | Mill extraction (pol in juice / pol in cane) | - |
Method and standards
Pol balance over the mill.
Where it is used
- Shift and daily mill control.
- Comparing milling tandems.
Common mistakes
- Gross mixed juice weight used.
- Bagasse % cane guessed instead of balanced.
Assumptions and limits
- Steady crush; pol by routine methods.
- Mixed juice must be the net weight after the drit correction; gross juice overstates pol % cane and extraction.
- Pol % cane here is by balance, not by direct cane analysis.
References
- Sugar factory chemical control (daily manufacturing report) definitions
- as compiled in SugarProcessTech
- Formulas for calculating sugar industry DMR
Questions and answers
Why is pol % cane computed and not measured?
Direct cane analysis is slow; the balance of juice and bagasse gives it every shift.
Is extraction the same as reduced extraction?
No: reduced extraction corrects to 12.5 % fibre so mills with different cane compare fairly.
Which mixed juice weight?
The net weight after the drit (suspended solids) correction.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.