FireCADCalc

Reduced Mill Extraction (Noël Deerr and Mittal)

Mill extraction reduced to the standard 12.5 % fibre in cane by Noël Deerr's and by Mittal's formulae, from actual extraction and fibre % cane.

Sugar mill and cogeneration

Inputs

Examples: e 91.85, fibre 14.5At standard fibre

Results

Both formulae assume pol lost per unit fibre is constant; they differ slightly away from 12.5 % fibre.

Deerr's loss term: pol not extracted per unit fibre, (1 − e)(1 − f)/f0.48057
Reduced extraction, Noël Deerr93.135%
Reduced extraction, Mittal92.974%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: e 91.85, fibre 14.5. The inputs, in the units selected above:

InputValue
Actual mill extraction91.850 %
Fibre % cane14.500 %

Applying the formula below gives:

ResultValue
Deerr's loss term: pol not extracted per unit fibre, (1 − e)(1 − f)/f0.48057
Reduced extraction, Noël Deerr93.135 %
Reduced extraction, Mittal92.974 %

Open this example in the calculator and change any input.

Formula

\(V = \frac{(1-e)(1-f)}{f}, \quad RME_{ND} = \frac{7 - V}{7}, \quad RME_M = 1 - \frac{0.125\,(1-e)}{f}\)

Variables

Symbol Meaning SI unit
\(e\) Actual mill extraction -
\(f\) Fibre % cane -
\(V\) Deerr's loss term: pol not extracted per unit fibre, (1 − e)(1 − f)/f -
\(RME_{ND}\) Reduced extraction, Noël Deerr -
\(RME_{M}\) Reduced extraction, Mittal -

Method and standards

Noël Deerr; Mittal.

Where it is used

  • Milling tandem performance.
  • Season and inter-factory comparison.

Common mistakes

  • Percentages entered as fractions in the formula.
  • Fibre % bagasse used for fibre % cane.

Assumptions and limits

  • Pol extraction basis; e and f are fractions in the formulas.

References

  • Noël Deerr reduced extraction to 12.5 % fibre: RME = 100 (7 − V)/7
  • V = (1 − e)(1 − f)/f
  • Mittal: RME = 100 [1 − 0.125 (1 − e)/f] with e and f as fractions (12.5 (1 − e)/f with f in per cent)
  • Sugar factory chemical control (daily manufacturing report) definitions
  • as compiled in SugarProcessTech
  • Formulas for calculating sugar industry DMR

Questions and answers

Why reduce to 12.5 % fibre?

Higher fibre traps more juice; reducing removes that effect so mills can be compared.

Deerr or Mittal?

Both are in use; report which one, and keep to it for trends.

What is 7 in Deerr's formula?

At 12.5 % fibre there are 7 parts of non-fibre per part of fibre: 87.5/12.5.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.