Worked example
Example: Hugot example. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Top roller angle (between feed and delivery roller centres) | 67.000 ° |
| Inclination of the housings from the vertical (towards the feed side) | 15.000 ° |
| Lift of the top roller | 10.000 mm |
Applying the formula below gives:
| Result | Value |
|---|---|
| Feed / delivery opening change ratio | 0.69873 |
| Feed opening increase | 6.6262 mm |
| Delivery opening increase | 9.4832 mm |
| Increase of either opening with vertical housings | 8.3389 mm |
Open this example in the calculator and change any input.
Formula
\(\mu = \frac{\cos(\alpha/2 + \beta)}{\cos(\alpha/2 - \beta)}, \quad \Delta E = \Delta h\cos(\alpha/2 + \beta), \quad \Delta e = \Delta h\cos(\alpha/2 - \beta)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\alpha\) | Top roller angle (between feed and delivery roller centres) | rad |
| \(\beta\) | Inclination of the housings from the vertical | rad |
| \(\Delta h\) | Lift of the top roller | m |
| \(\mu\) | Feed / delivery opening change ratio | - |
| \(\Delta E\) | Feed opening increase | m |
| \(\Delta e\) | Delivery opening increase | m |
| \(\Delta e_v\) | Increase of either opening with vertical housings | m |
Method and standards
Geometry of the lift along the inclined housing.
Where it is used
- Setting mills with inclined housings.
- Understanding opening changes under load.
Common mistakes
- Using the full angle α instead of α/2.
- Measuring β from the horizontal.
Assumptions and limits
- Small lifts; roller centres fixed otherwise.
- β is measured from the vertical towards the feed side, so that the delivery opens more than the feed; α/2 + β must stay below 90°.
References
- Hugot
- Handbook of Cane Sugar Engineering
- 3rd ed. (Elsevier, 1986)
- ch. 13
- eqns 13.9–13.10
- pp. 214–216
Questions and answers
Why incline the housings?
So the top roller lifts along the resultant of the forces on it; the delivery then opens more than the feed.
What is μ?
The ratio of the feed opening change to the delivery opening change for the same lift.
Vertical housings?
Both openings change by Δh cos(α/2).
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.