Worked example
Example: Hugot k_A example. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Fibre per unit cane | 13.400 % |
| Pol (sucrose) % juice | 14.540 % |
| Brix % juice | 17.360 % |
| Sugar made % cane | 10.820 % |
| Known coefficient for the recoverable sugar | 1.3900 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Cane quality term | 7.2687 % |
| Efficiency coefficient from the yield | 1.4886 |
| Recoverable sugar % cane with the known k | 10.103 % |
Open this example in the calculator and change any input.
Formula
\(X = k(1 - 1.65f)(S - 0.3B), \quad k = \frac{\rho}{(1 - 1.65f)(S - 0.3B)}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(f\) | Fibre per unit cane | - |
| \(S\) | Pol (sucrose) % juice | - |
| \(B\) | Brix % juice | - |
| \(\rho\) | Sugar made % cane | - |
| \(k\) | Known coefficient for the recoverable sugar | - |
| \((1 - 1.65f)(S - 0.3B)\) | Cane quality term | - |
| \(X\) | Recoverable sugar % cane with the known k | - |
Method and standards
Hugot's coefficient derived from the losses in bagasse and molasses.
Where it is used
- Valuing cane lots and varieties.
- Season factory performance.
Common mistakes
- Mixing primary and absolute juice analyses.
- Entering yields as percent numbers.
Assumptions and limits
- Standard losses folded into k.
- S and B and the known k must refer to the same juice (primary, crusher, mixed or absolute); the forms of k differ by a few points.
- Hugot's examples: f 0.134, B_A 17.36, S_A 14.54 and 10.82 % yield give k_A = 1.4886; k 1.39 with f 0.136, B 21.40, S 18.83 gives 13.38 % recoverable.
References
- Hugot
- Handbook of Cane Sugar Engineering
- 3rd ed. (Elsevier, 1986)
- ch. 21
- eqns 21.25–21.34 and Table 21.3
- pp. 342–350
Questions and answers
Where do 1.65 and 0.3 come from?
1.65 f approximates the bagasse loss at a standard extraction; 0.3 B is the molasses loss at a standard molasses purity (about 29).
Which forms of k?
Planters' k_P on fresh cane, factory k_U on primary juice, k_C on mixed-juice purity and k_A on absolute juice; they differ by a few points.
What is a good k?
Hugot: 1.38–1.42 in well-run factories on primary juice; 1.47–1.53 on absolute juice.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.