Heat Transfer Coefficient Over a Tube Bank (Zukauskas)

Gas-side convective heat transfer coefficient for cross-flow over an in-line or staggered bank of plain tubes, by the Zukauskas correlation, with Re and Nu.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliserBoilerEconomiser and air preheater

Inputs

Examples: Staggered boiler bank, 50.8 mm tubes, flue gas about 400 °C, 8 m/sIn-line economiser, 38.1 mm, flue gas about 200 °C, 10 m/sStaggered wide pitch, 31.8 mm, 6 m/s, 10 rows (C2 0.92)Slow in-line bank, Re about 25Staggered bank at 0.2 m/s, Re about 500

Take it from the Zukauskas row-correction table in a heat transfer text; 1 for deep banks.

Results

Re 100–1 000: the bank is treated as isolated cylinders (Zukauskas single-cylinder constants), as Incropera advises for this range.

Maximum velocity in the bank0.40650m/s
Reynolds number at maximum velocity516.26
Prandtl number of the gas0.73333
Nusselt number10.332
Heat transfer coefficient12.203W/(m²·K)

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Staggered boiler bank, 50.8 mm tubes, flue gas about 400 °C, 8 m/s. The inputs, in the units selected above:

InputValue
Tube arrangementStaggered
Tube outer diameter50.800 mm
Transverse pitch (across the flow)100.00 mm
Longitudinal pitch (along the flow)90.000 mm
Gas velocity approaching the bank8.0000 m/s
Gas density0.55000 kg/m³
Gas dynamic viscosity3.2000e-05 Pa·s
Gas thermal conductivity0.050000 W/(m·K)
Gas specific heat1.1500 kJ/(kg·K)
Prandtl number at the tube wall (0 = same as the gas)0 -
Correction for fewer than 20 rows (1 for 20 or more)1.0000 -

Applying the formula below gives:

ResultValue
Maximum velocity in the bank16.260 m/s
Reynolds number at maximum velocity14,197
Prandtl number of the gas0.73600
Nusselt number99.224
Heat transfer coefficient97.661 W/(m²·K)

Open this example in the calculator and change any input.

Formula

\(V_{max} = \frac{S_T}{S_T - D} V \quad \text{or} \quad \frac{S_T}{2(S_D - D)} V\)

\(Re_{D,max} = \frac{\rho V_{max} D}{\mu}, \quad Pr = \frac{c_p \mu}{k}\)

\(Nu_D = C_2\, C\, Re_{D,max}^m Pr^{n} (Pr/Pr_s)^{1/4}, \quad h = Nu_D k / D\)

Variables

Symbol Meaning SI unit
\(D\) tube outer diameter m
\(S_T\) transverse pitch m
\(S_L\) longitudinal pitch m
\(S_D\) diagonal pitch, staggered m
\(V\) approach velocity m/s
\(\rho\) gas density kg/m³
\(\mu\) gas dynamic viscosity Pa·s
\(k\) gas thermal conductivity W/(m·K)
\(c_p\) gas specific heat J/(kg·K)
\(Pr_s\) Prandtl number at the wall -
\(C_2\) row correction for fewer than 20 rows -
\(C, m\) Zukauskas constants for arrangement and Re -
\(n\) Prandtl exponent: 0.36 (0.37 for the isolated-cylinder range with Pr up to 10) -
\(\text{arr}\) tube arrangement -
\(V_{max}\) maximum velocity m/s
\(Re_{D,max}\) Reynolds number -
\(Pr\) Prandtl number -
\(Nu_D\) Nusselt number -
\(h\) heat transfer coefficient W/(m²·K)

Method and standards

The Zukauskas correlation for banks of 20 or more rows, with constants for Re from 10 to 2 000 000 as tabulated by Incropera (Tables 7.5 and 7.6): from 10 to 100, C = 0.80 in-line and 0.90 staggered with m = 0.40; from 100 to 1 000 the bank is approximated as isolated cylinders (C = 0.51, m = 0.5, Pr exponent 0.37 up to Pr 10); from 1 000, in-line C = 0.27, m = 0.63 up to Re 2×10⁵; staggered C = 0.35 (S_T/S_L)^0.2 (or 0.40 when S_T/S_L ≥ 2), m = 0.60; above 2×10⁵ C = 0.021 or 0.022, m = 0.84. The maximum velocity is at the narrowest gap, transverse or diagonal.

Where it is used

  • Rating economisers, air heaters and boiler banks.
  • Checking the effect of a velocity or pitch change.
  • Estimating U for heat recovery equipment.

Common mistakes

  • Using approach velocity instead of maximum velocity in Re.
  • Taking gas properties at the inlet instead of the mean temperature.
  • Applying it to finned tubes: fins need their own correlation and efficiency.

Assumptions and limits

  • Plain tubes in cross-flow; Re 10 to 2 000 000; Pr 0.7 to 500. Below Re 1 000 the constants are less certain and the page says so.
  • Gas radiation not included (add it separately at high temperatures).
  • Row correction C₂ from the Zukauskas table for shallow banks.

References

  • Zukauskas (1972) tube-bank correlation (Incropera Tables 7.5–7.6)

Questions and answers

What gas-side coefficient does a boiler bank have?

Typically 50–150 W/(m²·K). The staggered 50.8 mm example at 8 m/s approach gives Re about 14 200 and h about 98 W/(m²·K).

Why staggered rather than in-line?

Staggered tubes break up the flow more and give a higher coefficient at the same velocity, at a higher pressure drop and with harder cleaning.

What gas properties should I use?

At the mean gas temperature in the bank; take them from the gas properties calculator for the flue gas composition.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.