Worked example
Example: Superheater tube: 0.8 kg/s steam, 38 mm ID, 66 bar(a), 450 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Flow through one tube | 2,880.0 kg/h |
| Tube inside diameter | 38.000 mm |
| Pressure (absolute) | 66.000 bar |
| Bulk temperature (single phase: water or superheated steam) | 450.00 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Heat transfer coefficient, Gnielinski | 2,549.0 W/(m²·K) |
| Heat transfer coefficient, Dittus–Boelter | 2,559.5 W/(m²·K) |
| Reynolds number | 1,006,443 |
| Prandtl number | 0.98306 |
| Velocity | 33.219 m/s |
Open this example in the calculator and change any input.
Formula
\(Re = \frac{\dot m\,d_i}{A\,\mu} \qquad f = (0.79\ln Re - 1.64)^{-2} \qquad Nu_G = \frac{(f/8)(Re - 1000)\,Pr}{1 + 12.7\sqrt{f/8}\,(Pr^{2/3} - 1)} \qquad h_G = \frac{Nu_G\,k}{d_i}\)
\(h_{DB} = 0.023\,Re^{0.8}\,Pr^{0.4}\,\frac{k}{d_i} \qquad v = \frac{\dot m}{\rho A}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m\) | flow through one tube | kg/s |
| \(d_i\) | tube inside diameter | m |
| \(p\) | pressure, absolute | Pa |
| \(T\) | bulk temperature | K |
| \(h_G\) | coefficient by Gnielinski | W/(m²·K) |
| \(h_{DB}\) | coefficient by Dittus–Boelter | W/(m²·K) |
| \(Re\) | Reynolds number | – |
| \(Pr\) | Prandtl number | – |
| \(v\) | velocity | m/s |
| \(f\) | Darcy friction factor (Petukhov) | – |
| \(Nu_G\) | Nusselt number | – |
| \(\mu\) | dynamic viscosity | Pa·s |
| \(k\) | thermal conductivity | W/(m·K) |
| \(\rho\) | density | kg/m³ |
| \(A\) | flow area | m² |
Method and standards
Gnielinski's correlation with Petukhov's smooth-tube friction factor, and Dittus–Boelter for comparison; properties from FireCAD's IAPWS-IF97 with IAPWS 2008 viscosity and 2011 conductivity at the bulk temperature. The conductivity omits the 2011 release's critical-enhancement term, as its industrial use allows; this makes h about 0.1–0.2 % low for hot water and medium-pressure steam, more near the critical point.
Where it is used
- Superheater and economiser design.
- Tube metal temperature checks.
- Overall coefficient calculations.
Common mistakes
- Using these correlations in boiling or laminar flow.
- Taking properties at the wall instead of the bulk temperature.
- Using the total flow instead of the flow per tube.
Assumptions and limits
- Fully developed turbulent single-phase flow in smooth tubes; no entrance effect or property-variation correction.
- Dittus–Boelter is evaluated with Pr^0.4, the exponent for a fluid being heated; for a fluid being cooled the exponent is 0.3. It is shown for comparison only; use the Gnielinski value.
References
- V. Gnielinski (1976) with Petukhov friction factor
- Dittus–Boelter (1930)
- IAPWS R7-97 IF97
- IAPWS 2008 viscosity
- IAPWS 2011 conductivity
Questions and answers
What is the steam-side coefficient in a superheater tube?
For 0.8 kg/s of steam at 66 bar(a) and 450 °C in a 38 mm bore, Re is 1.0 million and Gnielinski gives 2550 W/(m²·K); Dittus–Boelter gives 2561.
Gnielinski or Dittus–Boelter?
Gnielinski is more accurate, especially from Re 3000 to 10 000; the two agree in fully turbulent flow.
Can I use it for boiling?
No. Boiling tubes need a boiling correlation; this page refuses two-phase states.
Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.