Nucleate Pool Boiling Heat Flux (Rohsenow)

Nucleate pool boiling heat flux and coefficient of water from the wall superheat (Rohsenow), with IF97 properties and IAPWS surface tension.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolChemical and fertiliserIAPWS-IF97 (water and steam)Boiler

Inputs

Examples: 1 atm, 10 K10 bar, 5 K

0.013 for water on polished copper or stainless; others from tables.

Results

Valid in nucleate boiling below the critical heat flux; errors of ±100 % in q are typical of the correlation.

Heat flux84.462kW/m²
Boiling coefficient16,892W/(m²·K)
Critical heat flux, Zuber–Lienhard (C = 0.149)2,976.2kW/m²

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 1 atm, 10 K. The inputs, in the units selected above:

InputValue
Pressure (absolute)1.0132 bar
Wall superheat T_w − T_sat10.000 K
Surface–fluid constant0.013000 -
Prandtl exponent (1 for water)1.0000 -

Applying the formula below gives:

ResultValue
Heat flux139.72 kW/m²
Boiling coefficient13,972 W/(m²·K)
Critical heat flux, Zuber–Lienhard (C = 0.149)1,260.7 kW/m²

Open this example in the calculator and change any input.

Formula

\(q = \mu_l h_{fg}\left[\frac{g(\rho_l - \rho_v)}{\sigma}\right]^{1/2}\left(\frac{c_{p,l}\Delta T_e}{C_{sf} h_{fg} Pr_l^n}\right)^3, \quad h = \frac{q}{\Delta T_e}\)

\(q_{max} = 0.149\, h_{fg}\, \rho_v\left[\frac{\sigma g(\rho_l - \rho_v)}{\rho_v^2}\right]^{1/4}\)

Variables

Symbol Meaning SI unit
\(p\) Pressure (absolute) Pa
\(\Delta T_e\) Wall superheat T_w − T_sat K
\(C_{sf}\) Surface–fluid constant -
\(n\) Prandtl exponent (1 for water) -
\(q\) Heat flux W/m²
\(h\) Boiling coefficient W/(m²·K)
\(q_{max}\) Critical heat flux, Zuber–Lienhard W/m²
\(\mu_l\) Saturated liquid viscosity (IAPWS 2008) Pa·s
\(h_{fg}\) Enthalpy of evaporation (IF97) J/kg
\(\rho_l\) Saturated liquid density (IF97) kg/m³
\(\rho_v\) Saturated vapour density (IF97) kg/m³
\(\sigma\) Surface tension (IAPWS R1-76) N/m
\(c_{p,l}\) Saturated liquid specific heat (IF97) J/(kg·K)
\(Pr_l\) Saturated liquid Prandtl number -
\(g\) Standard gravity, 9.806 65 m/s²

Method and standards

Rohsenow's nucleate boiling correlation with saturation properties at the pressure; critical heat flux by Zuber with Lienhard's constant 0.149 (as in the critical heat flux calculator).

Where it is used

  • Evaporator and kettle reboiler checks.
  • Teaching boiling regimes.

Common mistakes

  • Using the surface constant of another fluid.

Assumptions and limits

  • Nucleate regime only: the page gives the critical heat flux (Zuber–Lienhard, C = 0.149, for a large flat heater) and warns when q exceeds it; above it the correlation does not apply.

References

  • Rohsenow (1952) q = μ_l h_fg [g(ρ_l − ρ_v)/σ]^½ [c_p ΔT/(C_sf h_fg Pr^n)]³ (Incropera); properties from IAPWS-IF97
  • IAPWS 2008/2011 and IAPWS R1-76 surface tension

Questions and answers

Why the cube?

Heat flux rises steeply with superheat in nucleate boiling: small ΔT changes mean large flux changes.

What is C_sf?

A constant for the surface–fluid pair; 0.013 is a common value for water on clean metals.

Upper limit?

The critical heat flux; beyond it the wall dries out.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.