Refractory Wall Heat Loss and Surface Temperature

Heat loss through a furnace or duct wall of up to three refractory and insulation layers, the interface and outer surface temperatures and the total loss.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliserBoilerBurner and furnace

Inputs

Examples: Furnace wall 1100 °C: 115 mm firebrick 1.2, 115 mm insulating brick 0.3, 75 mm block 0.08, 30 °C, h 12, 50 m²Duct lining 400 °C: 75 mm castable 0.9, 100 mm mineral wool 0.06, none, 30 °C, h 10, 100 m²Bare brick 800 °C: 230 mm firebrick 1.1, 30 °C, h 15, 10 m²

About 8–15 W/(m²·K) for painted casing in still air; more in wind.

Layer 1 (hot face)

Layer 2

Layer 3 (cold face)

Results

Check each interface temperature against the service limit of the next layer's material.

Heat loss per m²200.00W/m²
Outer surface temperature50.000°C
Total heat loss20.000kW
Interface temperature, layer 1 to 2383.33°C
Interface temperature, layer 2 to 350.000°C

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Furnace wall 1100 °C: 115 mm firebrick 1.2, 115 mm insulating brick 0.3, 75 mm block 0.08, 30 °C, h 12, 50 m². The inputs, in the units selected above:

InputValue
Hot face temperature1,100.0 °C
Thickness115.00 mm
Thermal conductivity at its mean temperature1.2000 W/(m·K)
Thickness (0 = none)115.00 mm
Thermal conductivity0.30000 W/(m·K)
Thickness (0 = none)75.000 mm
Thermal conductivity0.080000 W/(m·K)
Ambient temperature30.000 °C
Outer surface coefficient (convection + radiation)12.000 W/(m²·K)
Wall area50.000 m²

Applying the formula below gives:

ResultValue
Heat loss per m²713.33 W/m²
Outer surface temperature89.444 °C
Total heat loss35.667 kW
Interface temperature, layer 1 to 21,031.6 °C
Interface temperature, layer 2 to 3758.19 °C

Open this example in the calculator and change any input.

Formula

\(q = \frac{T_h - T_a}{\dfrac{t_1}{k_1} + \dfrac{t_2}{k_2} + \dfrac{t_3}{k_3} + \dfrac{1}{h_s}} \qquad T_{12} = T_h - q\frac{t_1}{k_1} \qquad T_{23} = T_{12} - q\frac{t_2}{k_2} \qquad T_s = T_a + \frac{q}{h_s}\)

Variables

Symbol Meaning SI unit
\(T_h\) hot face temperature K
\(t_1\) layer 1 thickness m
\(k_1\) layer 1 conductivity W/(m·K)
\(t_2\) layer 2 thickness m
\(k_2\) layer 2 conductivity W/(m·K)
\(t_3\) layer 3 thickness m
\(k_3\) layer 3 conductivity W/(m·K)
\(T_a\) ambient temperature K
\(h_s\) outer surface coefficient W/(m²·K)
\(A\) wall area m²
\(q\) heat loss per m² W/m²
\(T_s\) outer surface temperature K
\(\dot Q\) total heat loss W
\(T_{12}\) interface 1–2 K
\(T_{23}\) interface 2–3 K

Method and standards

Steady one-dimensional conduction through plane layers in series and a combined convection–radiation coefficient at the casing.

Where it is used

  • Refractory and insulation design of furnaces, ducts and flues.
  • Checking casing temperatures for personnel safety.
  • Valuing re-insulation.

Common mistakes

  • Using one conductivity for very different temperatures.
  • Ignoring anchors and joints, which leak heat.
  • Using the plane-wall equation for small cylinders.

Assumptions and limits

  • Plane wall; constant conductivities; no heat bridges.
  • One pass with fixed k and h_s. Refractory conductivity varies with temperature and the casing coefficient rises with casing temperature (radiation), so recheck each k at the computed layer mean temperature and h_s at the computed T_s, and recalculate if they differ.

References

  • One-dimensional conduction through plane layers in series with a surface coefficient

Questions and answers

How much heat does a furnace wall lose?

A 1100 °C wall of 115 mm firebrick, 115 mm insulating brick and 75 mm block loses 713 W/m², 36 kW over 50 m²; the casing runs at 90 °C and the interfaces at 1032 and 758 °C.

Why check the interfaces?

Each insulating layer has a maximum service temperature; if the interface is hotter, it shrinks or melts.

What conductivity should I use?

The maker's value at the layer's mean temperature; refractory conductivity changes with temperature.

Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators