Worked example
Example: Furnace wall 1100 °C: 115 mm firebrick 1.2, 115 mm insulating brick 0.3, 75 mm block 0.08, 30 °C, h 12, 50 m². The inputs, in the units selected above:
| Input | Value |
|---|---|
| Hot face temperature | 1,100.0 °C |
| Thickness | 115.00 mm |
| Thermal conductivity at its mean temperature | 1.2000 W/(m·K) |
| Thickness (0 = none) | 115.00 mm |
| Thermal conductivity | 0.30000 W/(m·K) |
| Thickness (0 = none) | 75.000 mm |
| Thermal conductivity | 0.080000 W/(m·K) |
| Ambient temperature | 30.000 °C |
| Outer surface coefficient (convection + radiation) | 12.000 W/(m²·K) |
| Wall area | 50.000 m² |
Applying the formula below gives:
| Result | Value |
|---|---|
| Heat loss per m² | 713.33 W/m² |
| Outer surface temperature | 89.444 °C |
| Total heat loss | 35.667 kW |
| Interface temperature, layer 1 to 2 | 1,031.6 °C |
| Interface temperature, layer 2 to 3 | 758.19 °C |
Open this example in the calculator and change any input.
Formula
\(q = \frac{T_h - T_a}{\dfrac{t_1}{k_1} + \dfrac{t_2}{k_2} + \dfrac{t_3}{k_3} + \dfrac{1}{h_s}} \qquad T_{12} = T_h - q\frac{t_1}{k_1} \qquad T_{23} = T_{12} - q\frac{t_2}{k_2} \qquad T_s = T_a + \frac{q}{h_s}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(T_h\) | hot face temperature | K |
| \(t_1\) | layer 1 thickness | m |
| \(k_1\) | layer 1 conductivity | W/(m·K) |
| \(t_2\) | layer 2 thickness | m |
| \(k_2\) | layer 2 conductivity | W/(m·K) |
| \(t_3\) | layer 3 thickness | m |
| \(k_3\) | layer 3 conductivity | W/(m·K) |
| \(T_a\) | ambient temperature | K |
| \(h_s\) | outer surface coefficient | W/(m²·K) |
| \(A\) | wall area | m² |
| \(q\) | heat loss per m² | W/m² |
| \(T_s\) | outer surface temperature | K |
| \(\dot Q\) | total heat loss | W |
| \(T_{12}\) | interface 1–2 | K |
| \(T_{23}\) | interface 2–3 | K |
Method and standards
Steady one-dimensional conduction through plane layers in series and a combined convection–radiation coefficient at the casing.
Where it is used
- Refractory and insulation design of furnaces, ducts and flues.
- Checking casing temperatures for personnel safety.
- Valuing re-insulation.
Common mistakes
- Using one conductivity for very different temperatures.
- Ignoring anchors and joints, which leak heat.
- Using the plane-wall equation for small cylinders.
Assumptions and limits
- Plane wall; constant conductivities; no heat bridges.
- One pass with fixed k and h_s. Refractory conductivity varies with temperature and the casing coefficient rises with casing temperature (radiation), so recheck each k at the computed layer mean temperature and h_s at the computed T_s, and recalculate if they differ.
References
- One-dimensional conduction through plane layers in series with a surface coefficient
Questions and answers
How much heat does a furnace wall lose?
A 1100 °C wall of 115 mm firebrick, 115 mm insulating brick and 75 mm block loses 713 W/m², 36 kW over 50 m²; the casing runs at 90 °C and the interfaces at 1032 and 758 °C.
Why check the interfaces?
Each insulating layer has a maximum service temperature; if the interface is hotter, it shrinks or melts.
What conductivity should I use?
The maker's value at the layer's mean temperature; refractory conductivity changes with temperature.
Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.