FireCADCalc

Natural Convection from a Vertical Plate (Churchill–Chu)

Natural convection coefficient and heat loss from a vertical plate or wall in air or water by the Churchill–Chu correlation, with Grashof and Rayleigh numbers.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliserIAPWS-IF97 (water and steam)

Inputs

Examples: 1 m wall at 70 °C in 20 °C airHot plate 0.3 m at 120 °C in 25 °C airHeater 0.2 m at 60 °C in 20 °C water

Results

Heat flow from one face; double it for a plate open on both sides. Properties at the film temperature. Radiation from the surface is extra and often as large as convection in air.

Rayleigh number at the film temperature1.3267e+08
Nusselt number66.787
Convection coefficient6.2496W/(m²·K)
Heat flow from one face of the plate89.056W

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 1 m wall at 70 °C in 20 °C air. The inputs, in the units selected above:

InputValue
FluidAir (dry)
Surface temperature70.000 °C
Fluid temperature away from the surface20.000 °C
Height of the plate1.0000 m
Width of the plate1.0000 m
Pressure (absolute)1.0132 bar

Applying the formula below gives:

ResultValue
Rayleigh number at the film temperature3.7579e+09
Nusselt number186.39
Convection coefficient4.9070 W/(m²·K)
Heat flow from one face of the plate245.35 W

Open this example in the calculator and change any input.

Formula

\(Ra_L = \frac{g\beta\,\Delta T\, L^3}{\nu\alpha}, \quad \overline{Nu}_L = \left\{0.825 + \frac{0.387 Ra_L^{1/6}}{\left[1 + (0.492/Pr)^{9/16}\right]^{8/27}}\right\}^2, \quad h = \frac{Nu\, k}{L}\)

Variables

Symbol Meaning SI unit
\(\text{fluid}\) Fluid -
\(T_s\) Surface temperature K
\(T_\infty\) Fluid temperature away from the surface K
\(L\) Height of the plate m
\(W\) Width of the plate m
\(p\) Pressure (absolute) Pa
\(Ra\) Rayleigh number at the film temperature -
\(Nu\) Nusselt number -
\(h\) Convection coefficient W/(m²·K)
\(\dot Q\) Heat flow from one face of the plate W

Method and standards

Churchill–Chu correlation for all Rayleigh numbers.

Where it is used

  • Heat loss from tanks, walls and panels.
  • Heat transfer examinations.

Common mistakes

  • Ignoring radiation.
  • Properties at the wrong temperature.

Assumptions and limits

  • Isothermal vertical surface, quiescent fluid; heat flow from one face of area L × W.
  • Water at or above its boiling point is rejected (boiling is not covered).

References

  • S.W. Churchill and H.H.S. Chu
  • Int. J. Heat Mass Transfer 18 (1975) 1323
  • Incropera
  • DeWitt
  • Bergman and Lavine
  • Fundamentals of Heat and Mass Transfer
  • ch. 9
  • Air from NIST Shomate
  • Sutherland and Eucken (engine); water from IAPWS-IF97 and the IAPWS 2008/2011 transport releases

Questions and answers

What h does a 1 m wall at 70 °C give in 20 °C air?

About 4.9 W/(m²·K), around 245 W per m² of wall.

Why the film temperature?

Properties are taken midway between surface and fluid.

What about radiation?

Add it: at these temperatures a painted surface radiates about as much again.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.