FireCADCalc

Natural Convection from a Horizontal Pipe (Churchill–Chu)

Natural convection coefficient and heat loss per metre from a horizontal pipe or cylinder in air or water by the Churchill–Chu correlation.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliserIAPWS-IF97 (water and steam)

Inputs

Examples: Bare 4-inch pipe at 150 °C in 20 °C airSmall tube 25 mm at 60 °C in 20 °C airHeating coil 30 mm at 80 °C in 30 °C water

Results

Convection only; radiation adds as much again for painted pipes in air.

Rayleigh number8.1153e+07
Nusselt number62.946
Convection coefficient1,355.5W/(m²·K)
Heat loss per metre6,387.7W/m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Bare 4-inch pipe at 150 °C in 20 °C air. The inputs, in the units selected above:

InputValue
FluidAir (dry)
Surface temperature150.00 °C
Fluid temperature20.000 °C
Outside diameter114.30 mm
Pressure (absolute)1.0132 bar

Applying the formula below gives:

ResultValue
Rayleigh number8,562,243
Nusselt number27.133
Convection coefficient6.8481 W/(m²·K)
Heat loss per metre319.68 W/m

Open this example in the calculator and change any input.

Formula

\(Ra_D = \frac{g\beta\,|T_s - T_\infty|\,D^3}{\nu\alpha}, \quad \overline{Nu}_D = \left\{0.60 + \frac{0.387 Ra_D^{1/6}}{\left[1 + (0.559/Pr)^{9/16}\right]^{8/27}}\right\}^2, \quad h = \frac{Nu\,k}{D}, \quad q' = h\pi D(T_s - T_\infty)\)

Variables

Symbol Meaning SI unit
\(\text{fluid}\) Fluid -
\(T_s\) Surface temperature K
\(T_\infty\) Fluid temperature K
\(D\) Outside diameter m
\(p\) Pressure (absolute) Pa
\(Ra\) Rayleigh number -
\(Nu\) Nusselt number -
\(h\) Convection coefficient W/(m²·K)
\(q'\) Heat loss per metre W/m

Method and standards

Churchill–Chu for horizontal cylinders.

Where it is used

  • Bare and insulated pipe losses.
  • Heat tracing.

Common mistakes

  • Forgetting radiation.
  • Using it for vertical pipes.

Assumptions and limits

  • Isothermal cylinder in still fluid; properties at the film temperature (T_s + T_∞)/2. β = 1/T for air (ideal gas); for water β from the IF97 density 0.5 K either side of the film temperature.
  • Ra up to 10¹² (a note is shown above it). Water at or above its boiling point is rejected (boiling is not covered).

References

  • S.W. Churchill and H.H.S. Chu
  • Int. J. Heat Mass Transfer 18 (1975) 1049
  • Incropera
  • DeWitt
  • Bergman and Lavine
  • Fundamentals of Heat and Mass Transfer
  • ch. 9
  • Air from NIST Shomate
  • Sutherland and Eucken (engine); water from IAPWS-IF97 and the IAPWS 2008/2011 transport releases

Questions and answers

A bare 4-inch pipe at 150 °C in 20 °C air?

About 6.8 W/(m²·K) by convection, roughly 320 W per metre; radiation adds a similar amount.

Why does diameter matter little?

h falls slowly as D grows, while area grows.

What range?

Ra up to 10¹².

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.