Heat Exchanger Area (Q = U·A·F·LMTD)

Heat transfer area a heat exchanger needs for a duty, from the overall coefficient U, the terminal temperatures (LMTD) and the correction factor F.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliserThermic fluid heatingBoiler

Inputs

Examples: Oil cooler 500 kW, U 300 W/m²K, counterflowEconomiser 4.2 MW, U 45 W/m²K, F = 0.97Steam heater 1.2 MW, U 1 500 W/m²K, steam 160 °C condensing

Clean or fouled, on the area basis you want the result in (usually the tube outside area).
For shell-and-tube exchangers with more than one tube pass, and for cross-flow, read F from the TEMA or textbook charts; 1 for true counterflow or a condensing or boiling stream.

Temperatures

Results

Heat transfer area required777.74m²
Conductance required34.998kW/K
Log mean temperature difference123.72K
Corrected mean temperature difference120.01K

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Oil cooler 500 kW, U 300 W/m²K, counterflow. The inputs, in the units selected above:

InputValue
Heat duty500.00 kW
Overall heat transfer coefficient300.00 W/(m²·K)
Hot stream inlet150.00 °C
Hot stream outlet90.000 °C
Cold stream inlet30.000 °C
Cold stream outlet70.000 °C
Flow arrangementCounterflow
LMTD correction factor (1 for pure counterflow)1.0000 -

Applying the formula below gives:

ResultValue
Heat transfer area required23.974 m²
Conductance required7.1921 kW/K
Log mean temperature difference69.521 K
Corrected mean temperature difference69.521 K

Open this example in the calculator and change any input.

Formula

\(A = \frac{Q}{U\,F\,\Delta T_{lm}} \qquad UA = \frac{Q}{F\,\Delta T_{lm}} \qquad \Delta T_{lm} = \frac{\Delta T_1 - \Delta T_2}{\ln(\Delta T_1/\Delta T_2)}\)

Variables

Symbol Meaning SI unit
\(Q\) heat duty W
\(U\) overall heat transfer coefficient W/(m²·K)
\(T_{h,in}\) hot stream inlet temperature K
\(T_{h,out}\) hot stream outlet temperature K
\(T_{c,in}\) cold stream inlet temperature K
\(T_{c,out}\) cold stream outlet temperature K
\(\text{flow}\) counterflow or parallel flow –
\(F\) LMTD correction factor –
\(A\) heat transfer area required m²
\(UA\) conductance required W/K
\(\Delta T_{lm}\) log mean temperature difference K
\(F\,\Delta T_{lm}\) corrected mean temperature difference K
\(\Delta T_1\), \(\Delta T_2\) terminal temperature differences K

Method and standards

The rate equation of a heat exchanger with the log mean temperature difference (Incropera, ch. 11). F for multi-pass and cross-flow arrangements comes from the charts for the exchanger type (TEMA, textbooks).

Where it is used

  • First sizing of shell-and-tube and plate exchangers.
  • Checking an exchanger for a new duty.
  • Comparing clean and fouled performance.

Common mistakes

  • Using a clean U without fouling factors.
  • Taking the LMTD without the multipass correction.
  • Mixing inside and outside area as the basis of U.

Assumptions and limits

  • Constant U along the exchanger. For a condensing or desuperheating section, split the exchanger into zones and add the areas.
  • The duty must agree with both streams' heat balances; check them with the steam or gas property calculators.
  • No allowance for plugged tubes or extra surface margin; add the design margin you need.
  • F applies to the counterflow LMTD; F below 1 with parallel flow, and F below 0.75, are flagged.

References

  • Incropera
  • Fundamentals of Heat and Mass Transfer
  • ch. 11; TEMA (F factor charts)

Questions and answers

How do I find the area of a heat exchanger?

A = Q/(U·F·LMTD). A 500 kW oil cooler with U = 300 W/(m²·K) and an LMTD of 69.5 K needs 24.0 m².

Where does U come from?

From the film coefficients of both streams, the wall and the fouling factors, or from the maker's data for the exchanger type. The calculator takes it as your input; the area is on the same basis as U (usually the tube outside area).

Why is an economiser so large?

Gas-side coefficients are low. A 4.2 MW economiser with U = 45 W/(m²·K) and a corrected mean difference of 120 K needs about 778 m².

Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.