Film Condensation of Steam on a Vertical Surface (Nusselt)

Average condensing heat transfer coefficient and condensation rate of saturated steam on a vertical wall or tube by Nusselt's film theory with IF97 properties.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliserIAPWS-IF97 (water and steam)

Inputs

Examples: Steam at 1 atm, 10 K, 1 m wallHeater shell at 4 bar(a), 15 K, 0.5 m tube of 25 mmVacuum 0.2 bar(a), 5 K, 2 m

Results

Film Reynolds number about 378 at the bottom, above 30: the film is wavy-laminar (or turbulent above about 1 800), where Incropera uses other correlations that give a higher coefficient; this wave-free result is conservative.

Laminar, wave-free film (Nusselt); real films ripple and give somewhat more. Non-condensable gas lowers the coefficient sharply.

Saturation temperature99.974°C
Modified latent heat h_fg + 0.68 c_p ΔT2,285.2kJ/kg
Average condensing coefficient6,418.4W/(m²·K)
Heat transferred6.4184kW
Condensate formed10.111kg/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Steam at 1 atm, 10 K, 1 m wall. The inputs, in the units selected above:

InputValue
Steam pressure (absolute)1.0132 bar
Saturation minus wall temperature10.000 K
Height of the surface1.0000 m
Width or tube circumference0.10000 m

Applying the formula below gives:

ResultValue
Saturation temperature99.974 °C
Modified latent heat h_fg + 0.68 c_p ΔT2,285.2 kJ/kg
Average condensing coefficient6,418.4 W/(m²·K)
Heat transferred6.4184 kW
Condensate formed10.111 kg/h

Open this example in the calculator and change any input.

Formula

\(\bar h = 0.943\left[\frac{\rho_l(\rho_l - \rho_v) g\, h'_{fg}\, k_l^3}{\mu_l L (T_{sat} - T_w)}\right]^{1/4}, \quad h'_{fg} = h_{fg} + 0.68 c_{p,l}\Delta T\)

Variables

Symbol Meaning SI unit
\(p\) Steam pressure (absolute) Pa
\(\Delta T\) Saturation minus wall temperature K
\(L\) Height of the surface m
\(W\) Width or tube circumference m
\(T_{sat}\) Saturation temperature K
\(h'_{fg}\) Modified latent heat h_fg + 0.68 c_p ΔT J/kg
\(\bar h\) Average condensing coefficient W/(m²·K)
\(\dot Q\) Heat transferred W
\(\dot m\) Condensate formed kg/s

Method and standards

Nusselt's laminar film analysis.

Where it is used

  • Condensers, heaters and steam-heated walls.
  • Heat transfer examinations.

Common mistakes

  • Superheated steam treated as saturated.
  • Ignoring non-condensables.

Assumptions and limits

  • Pure saturated steam, laminar wave-free film. The film Reynolds number Re_δ = 4ṁ/(μ_l b) is checked: above 30 (wavy-laminar) the result is conservative and a note appears.

References

  • W. Nusselt (1916) film condensation; Incropera
  • DeWitt
  • Bergman and Lavine
  • Fundamentals of Heat and Mass Transfer
  • ch. 10 (0.943 coefficient, h'fg = h_fg + 0.68 c_p ΔT)
  • IAPWS-IF97 (water and steam)

Questions and answers

Steam at 1 atm on a 1 m wall 10 K colder?

About 6 400 W/(m²·K) average.

Why so high?

Latent heat is released at the surface through a thin liquid film.

What lowers it in practice?

Air in the steam: a few per cent halves the coefficient.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.