Worked example
Example: Steam-water at 70 bar, 10 % quality, 1,000 kg/(m2 s), 50 mm riser. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Vapour mass fraction (quality) | 10.000 % |
| Liquid density | 739.70 kg/m³ |
| Vapour density | 36.500 kg/m³ |
| Liquid viscosity | 0.091000 mPa·s |
| Vapour viscosity | 0.019000 mPa·s |
| Total mass flux | 1,000.0 kg/(m²·s) |
| Pipe inside diameter | 50.000 mm |
| Surface tension | 17.600 mN/m |
Applying the formula below gives:
| Result | Value |
|---|---|
| Lockhart–Martinelli parameter (turbulent–turbulent) | 1.8770 |
| Two-phase multiplier | 11.939 |
| Void fraction, homogeneous | 69.247 % |
| Density, homogeneous | 252.75 kg/m³ |
| Void fraction, Lockhart–Martinelli | 71.059 % |
| Density, Lockhart–Martinelli | 240.01 kg/m³ |
| Slip ratio, Chisholm | 1.7107 |
| Void fraction, Chisholm | 56.827 % |
| Density, Chisholm | 340.09 kg/m³ |
| Slip ratio, CISE | 1.3569 |
| Void fraction, CISE | 62.398 % |
| Density, CISE | 300.92 kg/m³ |
Open this example in the calculator and change any input.
Formula
\(\alpha = \frac{x}{x + S(1 - x)\rho_V/\rho_L}, \quad \rho_{tp} = \alpha\rho_V + (1 - \alpha)\rho_L, \quad X_{tt} = \left(\frac{1 - x}{x}\right)^{0.9}\left(\frac{\rho_V}{\rho_L}\right)^{0.5}\left(\frac{\mu_L}{\mu_V}\right)^{0.1}\)
\(\alpha_{LM} = \frac{\phi_L - 1}{\phi_L}, \ \phi_L^2 = 1 + \frac{20}{X_{tt}} + \frac{1}{X_{tt}^2}, \quad S_{Ch} = (\rho_L/\rho_V)^{1/4}\ (X \le 1), \quad S_{CISE} = 1 + E_1\left(\frac{y}{1 + yE_2} + yE_2\right)^{1/2}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(x\) | Vapour mass fraction (quality) | - |
| \(\rho_L\) | Liquid density | kg/m³ |
| \(\rho_V\) | Vapour density | kg/m³ |
| \(\mu_L\) | Liquid viscosity | Pa·s |
| \(\mu_V\) | Vapour viscosity | Pa·s |
| \(G\) | Total mass flux | kg/(m²·s) |
| \(D\) | Pipe inside diameter | m |
| \(\sigma\) | Surface tension | N/m |
| \(X_{tt}\) | Lockhart–Martinelli parameter (turbulent–turbulent) | - |
| \(\phi_L^2\) | Two-phase multiplier | - |
| \(\alpha_{hom}\) | Void fraction, homogeneous | - |
| \(\rho_{hom}\) | Density, homogeneous | kg/m³ |
| \(\alpha_{LM}\) | Void fraction, Lockhart–Martinelli | - |
| \(\rho_{LM}\) | Density, Lockhart–Martinelli | kg/m³ |
| \(S_{Ch}\) | Slip ratio, Chisholm | - |
| \(\alpha_{Ch}\) | Void fraction, Chisholm | - |
| \(\rho_{Ch}\) | Density, Chisholm | kg/m³ |
| \(S_{CISE}\) | Slip ratio, CISE | - |
| \(\alpha_{CISE}\) | Void fraction, CISE | - |
| \(\rho_{CISE}\) | Density, CISE | kg/m³ |
Method and standards
Slip-ratio and separated-flow void fraction models.
Where it is used
- Thermosyphon reboiler and natural circulation loop heads.
- Two-phase line hydrostatics.
Common mistakes
- Using the homogeneous density for static head.
- Mixing volume and mass quality.
Assumptions and limits
- Adiabatic, steady two-phase flow; turbulent–turbulent Lockhart–Martinelli.
Questions and answers
Why do the densities differ so much?
At high void fraction a small change in α changes the liquid holdup, and the liquid dominates the density.
Which method is best?
Chisholm's slip ratio performed best for density among 14 methods in his comparison and works for vertical and horizontal flow; CISE is for vertical upflow.
What do the defaults represent?
An illustrative case: Steam-water at 70 bar, 10 % quality, 1,000 kg/(m2 s), 50 mm riser. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Serth, Process Heat Transfer: Principles and Applications (Academic Press, 2007), sec. 9.4, eqs. 9.28, 9.37 and 9.51 to 9.67 and Examples 9.5 and 9.6 (Chisholm, 1983; Premoli et al., 1971)