Worked example
Example: Illustrative 300 mm and 250 mm pipes. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Length, pipe 1 | 300.00 m |
| Diameter, pipe 1 | 300.00 mm |
| Length, pipe 2 | 200.00 m |
| Diameter, pipe 2 | 250.00 mm |
| Length, pipe 3 (0 = none) | 0 m |
| Diameter, pipe 3 | 200.00 mm |
Applying the formula below gives:
| Result | Value |
|---|---|
| Series: equivalent length of diameter D₁ | 797.66 m |
| Parallel: equivalent diameter of length L₁ | 377.52 mm |
| Parallel: share of flow in pipe 1 | 56.293 % |
| Parallel: share in pipe 2 | 43.707 % |
| Parallel: share in pipe 3 | 0 % |
Open this example in the calculator and change any input.
Formula
\(L_e = D_1^5\sum\frac{L_i}{D_i^5}, \quad \frac{q_i}{Q} = \frac{D_i^{2.5}/\sqrt{L_i}}{\sum D_j^{2.5}/\sqrt{L_j}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(L_1\) | Length, pipe 1 | m |
| \(D_1\) | Diameter, pipe 1 | m |
| \(L_2\) | Length, pipe 2 | m |
| \(D_2\) | Diameter, pipe 2 | m |
| \(L_3\) | Length, pipe 3 (0 = none) | m |
| \(D_3\) | Diameter, pipe 3 | m |
| \(L_e\) | Series: equivalent length of diameter D₁ | m |
| \(D_e\) | Parallel: equivalent diameter of length L₁ | m |
| \(q_1/Q\) | Parallel: share of flow in pipe 1 | - |
| \(q_2/Q\) | Parallel: share in pipe 2 | - |
| \(q_3/Q\) | Parallel: share in pipe 3 | - |
Method and standards
Series and parallel pipes.
Where it is used
- Water mains and process piping networks.
- Fluid mechanics examinations.
Common mistakes
- Adding diameters instead of conveyance.
- Ignoring different friction factors.
Assumptions and limits
- Equal friction factors; minor losses neglected.
References
- Dupuit's equivalent pipe and parallel pipe relations with a common friction factor
Questions and answers
What single 300 mm pipe equals 300 m of 300 mm plus 200 m of 250 mm in series?
About 798 m of 300 mm pipe.
How does flow split between them in parallel?
About 56 % through the 300 mm pipe and 44 % through the 250 mm pipe.
What do the defaults represent?
An illustrative 300 m of 300 mm pipe with 200 m of 250 mm pipe, in series and in parallel.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.