Worked example
Example: Illustrative 2 mm water drop at 2 m/s. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Liquid density | 998.00 kg/m³ |
| Density difference with the surrounding fluid | 997.00 kg/m³ |
| Liquid viscosity | 1.0000 mPa·s |
| Surface tension | 72.800 mN/m |
| Velocity | 2.0000 m/s |
| Length scale (drop or jet diameter) | 2.0000 mm |
Applying the formula below gives:
| Result | Value |
|---|---|
| Weber number ρV²L/σ | 109.67 |
| Bond number ΔρgL²/σ | 0.53721 |
| Capillary number μV/σ | 0.027473 |
| Ohnesorge number μ/√(ρσL) | 0.002623 |
| Capillary length √(σ/Δρg) | 2.7287 mm |
Open this example in the calculator and change any input.
Formula
\(We = \frac{\rho V^2L}{\sigma}, \quad Bo = \frac{\Delta\rho gL^2}{\sigma}, \quad Ca = \frac{\mu V}{\sigma}, \quad Oh = \frac{\mu}{\sqrt{\rho\sigma L}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\rho\) | Liquid density | kg/m³ |
| \(\Delta\rho\) | Density difference with the surrounding fluid | kg/m³ |
| \(\mu\) | Liquid viscosity | Pa·s |
| \(\sigma\) | Surface tension | N/m |
| \(V\) | Velocity | m/s |
| \(L\) | Length scale (drop or jet diameter) | m |
| \(We\) | Weber number ρV²L/σ | - |
| \(Bo\) | Bond number ΔρgL²/σ | - |
| \(Ca\) | Capillary number μV/σ | - |
| \(Oh\) | Ohnesorge number μ/√(ρσL) | - |
| \(\ell_c\) | Capillary length √(σ/Δρg) | m |
Method and standards
Capillary numbers.
Where it is used
- Sprays, atomisers, inkjets and bubble columns.
- Microfluidics and coating flows.
Common mistakes
- Using the wrong length scale.
- Using liquid density instead of the density difference for Bond number.
Assumptions and limits
- Clean interfaces; constant properties; g = 9.80665 m/s².
References
- Dimensionless groups of capillarity
Questions and answers
Which length should I use?
The drop, bubble, jet or channel diameter that controls the problem.
Why use the density difference in the Bond number?
Buoyancy depends on the difference between the two fluids' densities.
What do the defaults represent?
An illustrative 2 mm water drop at 20 °C moving at 2 m/s through air.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
White, Fluid Mechanics, 7th ed. (McGraw-Hill, 2011)