FireCADCalc

Two-Phase Pressure Drop by the Homogeneous Model

Frictional pressure drop of a gas–liquid flow in a pipe by the homogeneous model with McAdams viscosity and Colebrook friction, and mixture density and velocity.

Thermal power plantProcess steam and utilitiesRefinery and petrochemical

Inputs

Examples: Illustrative 5 kg/s at 10 % qualityFlashing condensate 2 kg/s, 5 %Refrigerant 0.5 kg/s, 40 %

Accepted: 3.6 to 36,000,000 kg/h
Accepted: 5 to 2,000 mm
Accepted: 0 to 100 %
Accepted: 100 to 2,000 kg/m³
Accepted: 0.05 to 500 kg/m³
Accepted: 0.01 to 1,000 mPa·s
Accepted: 0.001 to 1 mPa·s
Accepted: 0 to 5 mm
Accepted: 0.1 to 100,000 m

Results

Homogeneous model: phases move at the same velocity, ρ_m = 1/(x/ρ_g + (1 − x)/ρ_l), 1/μ_m = x/μ_g + (1 − x)/μ_l; Δp = f(L/D)G²/(2ρ_m). Good at high mass flux and for bubbly or mist flow; separated-flow correlations are better for stratified and annular flow. Acceleration and static head are not included.

Homogeneous mixture density47.619kg/m³
Mixture viscosity (McAdams)0.078947mPa·s
Mixture velocity13.369m/s
Reynolds number806,385
Darcy friction factor0.016980
Frictional pressure drop36.129kPa

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 5 kg/s at 10 % quality. The inputs, in the units selected above:

InputValue
Total mass flow18,000 kg/h
Pipe inside diameter100.00 mm
Vapour (gas) mass quality10.000 %
Liquid density900.00 kg/m³
Gas density5.0000 kg/m³
Liquid viscosity0.15000 mPa·s
Gas viscosity0.015000 mPa·s
Pipe roughness0.045000 mm
Pipe length50.000 m

Applying the formula below gives:

ResultValue
Homogeneous mixture density47.619 kg/m³
Mixture viscosity (McAdams)0.078947 mPa·s
Mixture velocity13.369 m/s
Reynolds number806,385
Darcy friction factor0.016980
Frictional pressure drop36.129 kPa

Open this example in the calculator and change any input.

Formula

\(\rho_m = \left(\frac{x}{\rho_g} + \frac{1 - x}{\rho_l}\right)^{-1}, \quad \Delta p_f = f\frac{L}{D}\frac{G^2}{2\rho_m}\)

Variables

Symbol Meaning SI unit
\(\dot m\) Total mass flow kg/s
\(D\) Pipe inside diameter m
\(x\) Vapour (gas) mass quality -
\(\rho_l\) Liquid density kg/m³
\(\rho_g\) Gas density kg/m³
\(\mu_l\) Liquid viscosity Pa·s
\(\mu_g\) Gas viscosity Pa·s
\(\varepsilon\) Pipe roughness m
\(L\) Pipe length m
\(\rho_m\) Homogeneous mixture density kg/m³
\(\mu_m\) Mixture viscosity (McAdams) Pa·s
\(v_m\) Mixture velocity m/s
\(Re\) Reynolds number -
\(f\) Darcy friction factor -
\(\Delta p_f\) Frictional pressure drop Pa

Method and standards

Homogeneous model.

Where it is used

  • Flashing condensate and refrigerant lines.
  • Two-phase relief and process lines.

Common mistakes

  • Using it for stratified flow.
  • Forgetting acceleration pressure drop in flashing lines.

Assumptions and limits

  • Equal phase velocities; adiabatic; constant quality.

References

  • Homogeneous equilibrium model

Questions and answers

When is the homogeneous model reasonable?

At high mass flux, in flashing flows and in bubbly or dispersed flows where the phases slip little.

Why does a little gas raise pressure drop so much?

Gas lowers the mixture density, so the velocity rises sharply for the same mass flow.

What do the defaults represent?

An illustrative 5 kg/s of a light hydrocarbon at 10 % vapour quality in a 100 mm pipe over 50 m.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Collier and Thome, Convective Boiling and Condensation, 3rd ed. (Oxford, 1994), ch. 2

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.