FireCADCalc

Two-Phase Void Fraction and Density: Homogeneous, L-M, Chisholm, CISE

Void fraction and two-phase density of a gas–liquid or steam–water flow by the homogeneous, Lockhart–Martinelli, Chisholm and CISE methods, with Xtt.

Process steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Steam-water at 70 bar, 10 % quality, 1,000 kg/(m2 s), 50 mm riserAir-water at 2 bar, 1 % quality (X above 1)

Accepted: 0.01 to 99.99 %
Accepted: 1 to 2,000 kg/m³
Accepted: 0.01 to 1,000 kg/m³
Accepted: 0.001 to 1,000 mPa·s
Accepted: 1E-4 to 1 mPa·s
Accepted: 1 to 50,000 kg/(m²·s)
Accepted: 2 to 2,000 mm
Accepted: 0.1 to 100 mN/m

Results

Void fractions from the methods usually agree within about 10 %, but two-phase densities can differ by a factor of two or more; for hydrostatic head in thermosyphon and natural-circulation loops use a slip model (Chisholm or CISE), not the homogeneous density.

Lockhart–Martinelli parameter (turbulent–turbulent)4.5823
Two-phase multiplier5.4122
Void fraction, homogeneous80.770%
Density, homogeneous193.85kg/m³
Void fraction, Lockhart–Martinelli57.016%
Density, Lockhart–Martinelli430.35kg/m³
Slip ratio, Chisholm2.2690
Void fraction, Chisholm64.927%
Density, Chisholm351.59kg/m³
Slip ratio, CISE2.8150
Void fraction, CISE59.874%
Density, CISE401.90kg/m³

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Steam-water at 70 bar, 10 % quality, 1,000 kg/(m2 s), 50 mm riser. The inputs, in the units selected above:

InputValue
Vapour mass fraction (quality)10.000 %
Liquid density739.70 kg/m³
Vapour density36.500 kg/m³
Liquid viscosity0.091000 mPa·s
Vapour viscosity0.019000 mPa·s
Total mass flux1,000.0 kg/(m²·s)
Pipe inside diameter50.000 mm
Surface tension17.600 mN/m

Applying the formula below gives:

ResultValue
Lockhart–Martinelli parameter (turbulent–turbulent)1.8770
Two-phase multiplier11.939
Void fraction, homogeneous69.247 %
Density, homogeneous252.75 kg/m³
Void fraction, Lockhart–Martinelli71.059 %
Density, Lockhart–Martinelli240.01 kg/m³
Slip ratio, Chisholm1.7107
Void fraction, Chisholm56.827 %
Density, Chisholm340.09 kg/m³
Slip ratio, CISE1.3569
Void fraction, CISE62.398 %
Density, CISE300.92 kg/m³

Open this example in the calculator and change any input.

Formula

\(\alpha = \frac{x}{x + S(1 - x)\rho_V/\rho_L}, \quad \rho_{tp} = \alpha\rho_V + (1 - \alpha)\rho_L, \quad X_{tt} = \left(\frac{1 - x}{x}\right)^{0.9}\left(\frac{\rho_V}{\rho_L}\right)^{0.5}\left(\frac{\mu_L}{\mu_V}\right)^{0.1}\)

\(\alpha_{LM} = \frac{\phi_L - 1}{\phi_L}, \ \phi_L^2 = 1 + \frac{20}{X_{tt}} + \frac{1}{X_{tt}^2}, \quad S_{Ch} = (\rho_L/\rho_V)^{1/4}\ (X \le 1), \quad S_{CISE} = 1 + E_1\left(\frac{y}{1 + yE_2} + yE_2\right)^{1/2}\)

Variables

Symbol Meaning SI unit
\(x\) Vapour mass fraction (quality) -
\(\rho_L\) Liquid density kg/m³
\(\rho_V\) Vapour density kg/m³
\(\mu_L\) Liquid viscosity Pa·s
\(\mu_V\) Vapour viscosity Pa·s
\(G\) Total mass flux kg/(m²·s)
\(D\) Pipe inside diameter m
\(\sigma\) Surface tension N/m
\(X_{tt}\) Lockhart–Martinelli parameter (turbulent–turbulent) -
\(\phi_L^2\) Two-phase multiplier -
\(\alpha_{hom}\) Void fraction, homogeneous -
\(\rho_{hom}\) Density, homogeneous kg/m³
\(\alpha_{LM}\) Void fraction, Lockhart–Martinelli -
\(\rho_{LM}\) Density, Lockhart–Martinelli kg/m³
\(S_{Ch}\) Slip ratio, Chisholm -
\(\alpha_{Ch}\) Void fraction, Chisholm -
\(\rho_{Ch}\) Density, Chisholm kg/m³
\(S_{CISE}\) Slip ratio, CISE -
\(\alpha_{CISE}\) Void fraction, CISE -
\(\rho_{CISE}\) Density, CISE kg/m³

Method and standards

Slip-ratio and separated-flow void fraction models.

Where it is used

  • Thermosyphon reboiler and natural circulation loop heads.
  • Two-phase line hydrostatics.

Common mistakes

  • Using the homogeneous density for static head.
  • Mixing volume and mass quality.

Assumptions and limits

  • Adiabatic, steady two-phase flow; turbulent–turbulent Lockhart–Martinelli.

Questions and answers

Why do the densities differ so much?

At high void fraction a small change in α changes the liquid holdup, and the liquid dominates the density.

Which method is best?

Chisholm's slip ratio performed best for density among 14 methods in his comparison and works for vertical and horizontal flow; CISE is for vertical upflow.

What do the defaults represent?

An illustrative case: Steam-water at 70 bar, 10 % quality, 1,000 kg/(m2 s), 50 mm riser. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Serth, Process Heat Transfer: Principles and Applications (Academic Press, 2007), sec. 9.4, eqs. 9.28, 9.37 and 9.51 to 9.67 and Examples 9.5 and 9.6 (Chisholm, 1983; Premoli et al., 1971)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.