FireCADCalc

Electricity Bill by Slab (Telescopic) Tariff

Energy charge, duty and total of an electricity bill under a slab (telescopic) tariff with up to four slabs, a fixed charge and electricity duty.

Inputs

Examples: Illustrative 350 unitsLow use, 80 unitsHigh use, 900 units

Accepted: 0 to 10,000,000
Accepted: 0 to 10,000,000
Accepted: 0 to 1,000
Accepted: 0 to 10,000,000
Accepted: 0 to 1,000
Accepted: 0 to 10,000,000
Accepted: 0 to 1,000
Accepted: 0 to 1,000
Accepted: 0 to 10,000,000
Accepted: 0 to 50 %

Results

Under a telescopic tariff each slab's units are charged at that slab's rate: the first slab at the lowest rate, the next units at the next rate and so on. The fixed (demand or meter) charge and duty are added. The marginal rate, the price of one more unit including duty, is what an energy saving actually saves. Some tariffs instead charge all units at the rate of the slab reached; this calculator follows the telescopic method.

Energy charge6,150.0
Duty307.50
Total bill6,657.5
Average cost per kWh7.3972
Marginal rate (price of the next kWh)8.4000

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 350 units. The inputs, in the units selected above:

InputValue
Units consumed in the billing period (kWh)350.00 -
End of slab 1 (kWh)100.00 -
Rate in slab 1 per kWh3.0000 -
End of slab 2 (kWh)200.00 -
Rate in slab 24.5000 -
End of slab 3 (kWh)400.00 -
Rate in slab 36.0000 -
Rate above slab 37.5000 -
Fixed charge for the period120.00 -
Electricity duty on the energy charge6.0000 %

Applying the formula below gives:

ResultValue
Energy charge1,650.0
Duty99.000
Total bill1,869.0
Average cost per kWh5.3400
Marginal rate (price of the next kWh)6.3600

Open this example in the calculator and change any input.

Formula

\(C_e = \sum_i c_i\,\max\left[0, \min(U, U_i) - U_{i-1}\right], \quad C = C_e(1 + d) + F\)

Variables

Symbol Meaning SI unit
\(U\) Units consumed in the billing period (kWh) -
\(U_1\) End of slab 1 (kWh) -
\(c_1\) Rate in slab 1 per kWh -
\(U_2\) End of slab 2 (kWh) -
\(c_2\) Rate in slab 2 -
\(U_3\) End of slab 3 (kWh) -
\(c_3\) Rate in slab 3 -
\(c_4\) Rate above slab 3 -
\(F\) Fixed charge for the period -
\(d\) Electricity duty on the energy charge -
\(C_e\) Energy charge -
\(C_d\) Duty -
\(C\) Total bill -
\(\bar c\) Average cost per kWh -
\(c_m\) Marginal rate (price of the next kWh) -

Method and standards

Slab tariff.

Where it is used

  • Household and shop electricity bills.
  • Checking the value of energy savings.

Common mistakes

  • Valuing savings at the average rate.
  • Applying the top rate to all units on a telescopic tariff.

Assumptions and limits

  • Telescopic slabs; one billing period.

References

  • Telescopic (slab-wise) tariff arithmetic

Questions and answers

How is a slab bill calculated?

The first 100 units at slab 1's rate, the next 100 at slab 2's rate and so on, plus fixed charge and duty.

What does a saving of one unit save?

The marginal rate of the slab you are in, plus duty, not the average rate.

What do the defaults represent?

An illustrative domestic tariff: 0–100 at 3.0, 101–200 at 4.5, 201–400 at 6.0, above at 7.5, fixed charge 120, duty 6 %, 350 units used.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.