FireCADCalc

Swinburne Test: DC Machine Losses and Efficiency

Constant losses of a DC shunt machine from its no-load (Swinburne) test, and its efficiency as a motor and as a generator at a chosen load current.

Inputs

Examples: Illustrative 220 V machine at 50 ALarge 460 V machine at 300 ALight load 10 A

Accepted: 6 to 3,000 V
Accepted: 0.01 to 1,000 A
Accepted: 0.001 to 100 A
Accepted: 0.001 to 50 Ω
Accepted: 0.1 to 10,000 A

Results

Run the machine light as a motor at rated voltage and speed: its input minus the small armature copper loss is the constant loss (iron, friction and windage, shunt field). At load, add the armature copper loss I_A²R_A: as a motor I_A = I_L − I_sh, as a generator I_A = I_L + I_sh. Efficiency peaks where copper loss equals constant loss. The test ignores the extra iron loss and armature reaction at load, so it slightly overestimates efficiency.

Constant losses (iron, friction, field)5,517.8W
Efficiency as a motor94.090%
Efficiency as a generator94.339%
Armature current for maximum efficiency428.87A

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 220 V machine at 50 A. The inputs, in the units selected above:

InputValue
Supply voltage220.00 V
No-load line current4.0000 A
Shunt field current1.2000 A
Armature resistance (hot)0.25000 Ω
Load line current50.000 A

Applying the formula below gives:

ResultValue
Constant losses (iron, friction, field)878.04 W
Efficiency as a motor86.605 %
Efficiency as a generator87.765 %
Armature current for maximum efficiency59.263 A

Open this example in the calculator and change any input.

Formula

\(P_c = VI_0 - (I_0 - I_{sh})^2R_A, \quad \eta_m = \frac{VI_L - P_c - I_A^2R_A}{VI_L}, \quad \eta_g = \frac{VI_L}{VI_L + P_c + I_A^2R_A}\)

Variables

Symbol Meaning SI unit
\(V\) Supply voltage V
\(I_0\) No-load line current A
\(I_{sh}\) Shunt field current A
\(R_A\) Armature resistance (hot) Ω
\(I_L\) Load line current A
\(P_c\) Constant losses (iron, friction, field) W
\(\eta_m\) Efficiency as a motor -
\(\eta_g\) Efficiency as a generator -
\(I_{A,\eta max}\) Armature current for maximum efficiency A

Method and standards

Swinburne test.

Where it is used

  • DC machine testing and teaching.
  • Estimating efficiency without a load bank.

Common mistakes

  • Using cold armature resistance.
  • Forgetting field current in armature current.

Assumptions and limits

  • Constant losses unchanged with load; brush drop neglected.

References

  • Swinburne (no-load) test

Questions and answers

Why is it called an indirect test?

Efficiency is calculated from losses, not measured by loading the machine.

Where is efficiency highest?

Where variable copper loss equals the constant losses.

What do the defaults represent?

An illustrative 220 V shunt machine taking 4 A light with 1.2 A field current and 0.25 Ω armature, evaluated at 50 A.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Chapman, Electric Machinery Fundamentals, 5th ed. (McGraw-Hill, 2012), Say, Performance and Design of AC Machines, 3rd ed. (Pitman, 1958)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.