FireCADCalc

Motor RMS Torque for a Move Profile and Inertia Ratio

Acceleration, deceleration, peak and RMS torque of a motor driving a trapezoidal move profile with dwell, and the load-to-motor inertia ratio for servo sizing.

Inputs

Examples: Illustrative servo axisIndexing table, no dwellConveyor start-stop

Accepted: 1E-8 to 10,000 kg·m²
Accepted: 0 to 100,000 kg·m²
Accepted: 0 to 100,000 N·m
Accepted: 0.0095493 to 19,099 rpm
Accepted: 0.0001 to 10,000 s
Accepted: 0 to 100,000 s
Accepted: 0.0001 to 10,000 s
Accepted: 0 to 100,000 s

Results

Accelerating the total inertia J = J_m + J_L to speed n in t_a needs Jn/t_a on top of the load torque; decelerating needs −Jn/t_d plus the load torque (load friction helps braking). Motor heating follows the square of torque, so the thermally equivalent continuous torque is the RMS over the whole cycle including dwell, which must stay below the motor's continuous rating, while the peak must stay within its peak rating. Servo makers recommend inertia ratios below about 10:1 (lower for stiff, fast systems); a gearbox reduces the reflected load inertia by the ratio squared.

Torque during acceleration5.0159N·m
Torque during deceleration (braking negative)-1.0159N·m
Peak torque5.0159N·m
RMS torque over the cycle3.6188N·m
Inertia ratio5.0000
Peak power (end of acceleration)787.90W

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative servo axis. The inputs, in the units selected above:

InputValue
Motor rotor inertia1.2000e-04 kg·m²
Load inertia reflected to the motor shaft6.0000e-04 kg·m²
Load (friction and gravity) torque while moving0.80000 N·m
Running speed3,000.0 rpm
Acceleration time0.10000 s
Constant-speed time0.30000 s
Deceleration time0.10000 s
Dwell time (at rest)0.50000 s

Applying the formula below gives:

ResultValue
Torque during acceleration3.0619 N·m
Torque during deceleration (braking negative)-1.4619 N·m
Peak torque3.0619 N·m
RMS torque over the cycle1.1590 N·m
Inertia ratio5.0000
Peak power (end of acceleration)961.94 W

Open this example in the calculator and change any input.

Formula

\(T_{acc} = \frac{(J_m + J_L)\omega}{t_a} + T_L, \quad T_{rms} = \sqrt{\frac{T_{acc}^2t_a + T_L^2t_r + T_{dec}^2t_d}{t_a + t_r + t_d + t_w}}\)

Variables

Symbol Meaning SI unit
\(J_m\) Motor rotor inertia kg·m²
\(J_L\) Load inertia reflected to the motor shaft kg·m²
\(T_L\) Load (friction and gravity) torque while moving N·m
\(n\) Running speed rad/s
\(t_a\) Acceleration time s
\(t_r\) Constant-speed time s
\(t_d\) Deceleration time s
\(t_w\) Dwell time (at rest) s
\(T_{acc}\) Torque during acceleration N·m
\(T_{dec}\) Torque during deceleration (braking negative) N·m
\(T_{peak}\) Peak torque N·m
\(T_{rms}\) RMS torque over the cycle N·m
\(J_L/J_m\) Inertia ratio -
\(P_{peak}\) Peak power (end of acceleration) W

Method and standards

RMS torque.

Where it is used

  • Servo and stepper sizing for indexing axes.
  • Checking motor heating on cyclic duty.

Common mistakes

  • Leaving the dwell out of the cycle time.
  • Forgetting to reflect load inertia through the gear ratio squared.

Assumptions and limits

  • Trapezoidal speed profile; constant load torque while moving; no torque at rest.

References

  • RMS (thermally equivalent) torque of a duty cycle

Questions and answers

Why RMS rather than average torque?

Copper loss, and so heating, goes with current squared, and current with torque.

What inertia ratio is acceptable?

Often up to 5–10:1 for servos; belt drives and compliant couplings need lower ratios for stable tuning.

What do the defaults represent?

An illustrative servo axis: 1.2 × 10⁻⁴ kg·m² motor, 6 × 10⁻⁴ load, 0.8 N·m friction, 3,000 rpm in 0.1 s, 0.3 s run, 0.1 s stop and 0.5 s dwell.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Hughes and Drury, Electric Motors and Drives, 4th ed. (Newnes, 2013)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.