FireCADCalc

Brushless DC Motor: Kv, Kt, Speed, Torque and Efficiency

Torque constant from a BLDC or brushed DC motor's Kv rating, no-load and loaded speed, torque, output power and efficiency, and the current at peak efficiency.

Inputs

Examples: Illustrative 920 Kv drone motor at 15 ARobot gearmotor 90 Kv on 24 VBrushed 775 motor on 12 V

Accepted: 1 to 100,000
Accepted: 1 to 1,000 V
Accepted: 0.0001 to 100 Ω
Accepted: 0 to 100 A
Accepted: 0.01 to 1,000 A

Results

For a permanent-magnet DC or BLDC motor the back-EMF and torque constants are the same number in SI: K_t [N·m/A] = 1/K_v [rad/s per V] = 60/(2πK_v [rpm/V]). Speed ω = K_v(V − IR); torque = K_t(I − I₀), the no-load current covering friction and iron losses. Efficiency peaks at I ≈ √(I₀·V/R) = √(I₀I_stall). Controller losses and the trapezoidal/sinusoidal drive constant (about 5–10 %) are ignored.

Torque constant (N·m/A)0.10610
No-load speed2,151.9rpm
Speed at the current1,998.0rpm
Shaft torque0.30239N·m
Shaft power63.270W
Efficiency87.875%
Current at peak efficiency2.4495A

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 920 Kv drone motor at 15 A. The inputs, in the units selected above:

InputValue
Speed constant (rpm per volt)920.00 -
Supply voltage14.800 V
Winding resistance (phase to phase)0.080000 Ω
No-load current0.60000 A
Operating current15.000 A

Applying the formula below gives:

ResultValue
Torque constant (N·m/A)0.010380
No-load speed13,572 rpm
Speed at the current12,512 rpm
Shaft torque0.14947 N·m
Shaft power195.84 W
Efficiency88.216 %
Current at peak efficiency10.536 A

Open this example in the calculator and change any input.

Formula

\(K_t = \frac{60}{2\pi K_v}, \quad \omega = K_v(V - IR_m), \quad T = K_t(I - I_0), \quad I_{\eta,max} = \sqrt{I_0\frac{V}{R_m}}\)

Variables

Symbol Meaning SI unit
\(K_v\) Speed constant (rpm per volt) -
\(V\) Supply voltage V
\(R_m\) Winding resistance (phase to phase) Ω
\(I_0\) No-load current A
\(I\) Operating current A
\(K_t\) Torque constant (N·m/A) -
\(n_0\) No-load speed rad/s
\(n\) Speed at the current rad/s
\(T\) Shaft torque N·m
\(P_{out}\) Shaft power W
\(\eta\) Efficiency -
\(I_{\eta,max}\) Current at peak efficiency A

Method and standards

Motor constants.

Where it is used

  • Drone, RC and robotics motor selection.
  • Checking motor and battery pairing.

Common mistakes

  • Mixing rpm/V and rad/s/V.
  • Ignoring no-load current in torque.

Assumptions and limits

  • Linear motor model; constant resistance; ideal controller.

References

  • Permanent-magnet DC motor model

Questions and answers

Why is Kt the inverse of Kv?

Energy conservation: electrical power E·I equals mechanical power T·ω, so the volts-per-rad/s and N·m-per-amp constants are equal in SI units.

Where is a motor most efficient?

At a current where copper loss equals the fixed losses, about √(I₀·I_stall), usually well below maximum power.

What do the defaults represent?

An illustrative 920 Kv drone motor on 14.8 V (4S) with 0.08 Ω winding, 0.6 A no-load current, running at 15 A.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Hughes and Drury, Electric Motors and Drives, 5th ed. (Newnes, 2019)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.