Worked example
Example: 20 MW for 500 t/d. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Refiner motor power | 20.000 MW |
| Pulp production (oven-dry) | 500.00 t/d |
| Share of power appearing as steam | 90.000 % |
| Share recovered as clean steam (reboiler) | 70.000 % |
| Latent heat of the steam | 2,100.0 kJ/kg |
Applying the formula below gives:
| Result | Value |
|---|---|
| Specific refining energy | 960.00 kWh/t |
| Refiner steam generated | 30.857 t/h |
| Clean steam recovered | 21.600 t/h |
| Recovered steam per OD tonne | 1.0368 kg/kg |
Open this example in the calculator and change any input.
Formula
\(\dot m_s = \frac{P\phi}{h_{fg}}, \quad \dot m_r = \eta_r\dot m_s\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(P\) | Refiner motor power | W |
| \(\dot m_{OD}\) | Pulp production (oven-dry) | kg/s |
| \(\phi\) | Share of power appearing as steam | - |
| \(\eta_r\) | Share recovered as clean steam (reboiler) | - |
| \(h_{fg}\) | Latent heat of the steam | J/kg |
| \(E\) | Specific refining energy | J/kg |
| \(\dot m_{s}\) | Refiner steam generated | kg/s |
| \(\dot m_{r}\) | Clean steam recovered | kg/s |
| \(\dot m_r/\dot m_{OD}\) | Recovered steam per OD tonne | kg/kg |
Method and standards
Energy balance on the refiners.
Where it is used
- TMP mill heat recovery design.
Common mistakes
- Assuming all refiner steam is usable without a reboiler.
Assumptions and limits
- Refiner heat leaves as saturated steam: only the latent heat is counted. Superheat in the refiner steam and the sensible heat of the dilution water are not included.
References
- Smook
- Handbook for Pulp & Paper Technologists
- 3rd ed. (Angus Wilde, 2002)
- ch. 5.6 (TMP: most of the refining energy appears as steam, recovered in reboilers)
Questions and answers
Why does refining make steam?
Nearly all the motor power ends up as heat that boils the water in the chips.
Why a reboiler?
Refiner steam is contaminated with turpentine and fibre; a reboiler makes clean steam from it.
How much steam per tonne?
Often 1.5–2 t of clean steam per tonne of TMP.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.