Paper Machine Hood Exhaust Air

Dry air to exhaust from a paper machine dryer hood to carry away the evaporated water, from the supply and exhaust humidity, with the hood dew point check.

Pulp and paperIAPWS-IF97 (water and steam)

Inputs

Examples: 45 t/h water, 0.16 kg/kg exhaustOpen hood 0.08

Humidity ratio of the supply air: kg of water per kg of dry air.
Humidity ratio of the hood exhaust: closed hoods run about 120–180 g/kg, open hoods far lower.
Absolute pressure, normally the local barometric pressure.

Results

This exhaust humidity is below the closed-hood range (0.12–0.18 kg/kg): more air must be heated and exhausted for the same evaporation. Keep hood surfaces above the dew point.

Dry air exhausted294.12t/h
Water vapour partial pressure in the exhaust11.548kPa
Exhaust dew point48.651°C

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 45 t/h water, 0.16 kg/kg exhaust. The inputs, in the units selected above:

InputValue
Water evaporated45.000 t/h
Supply air humidity (per kg dry air)15.000 g/kg
Exhaust air humidity (per kg dry air)160.00 g/kg
Pressure in the hood (absolute)101.33 kPa

Applying the formula below gives:

ResultValue
Dry air exhausted310.34 t/h
Water vapour partial pressure in the exhaust20.733 kPa
Exhaust dew point60.839 °C

Open this example in the calculator and change any input.

Formula

\(\dot m_a = \frac{\dot E}{Y_e - Y_s}, \quad p_v = \frac{P\,Y_e}{0.621945 + Y_e}\)

Variables

Symbol Meaning SI unit
\(\dot E\) Water evaporated kg/s
\(Y_s\) Supply air humidity (per kg dry air) kg/kg
\(Y_e\) Exhaust air humidity (per kg dry air) kg/kg
\(P\) Pressure in the hood (absolute) Pa
\(\dot m_a\) Dry air exhausted kg/s
\(p_v\) Water vapour partial pressure in the exhaust Pa
\(T_{dp}\) Exhaust dew point K

Method and standards

Water balance on the hood air.

Where it is used

  • Hood and heat recovery design.

Common mistakes

  • Using wet air flow as dry air.
  • Ignoring air leaking into the hood.

Assumptions and limits

  • All evaporated water leaves with the exhaust.
  • Humidities are humidity ratios (kg water per kg dry air); the pressure is absolute.

References

  • Smook
  • Handbook for Pulp & Paper Technologists
  • 3rd ed. (Angus Wilde, 2002)
  • ch. 17 (drying: hood ventilation and heat recovery)
  • Psychrometric humidity ratio Y = 0.621945 p_v/(P − p_v); saturation from IAPWS-IF97

Questions and answers

Why run the hood humid?

Less air carries the same water, so less air must be heated and exhausted.

What limits humidity?

Condensation dripping on the sheet if hood surfaces fall below the dew point.

Where does the exhaust heat go?

To heat recovery towers for supply air and process water.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.