FireCADCalc

Saturated Water Properties

Saturation pressure, enthalpy, density, specific heat, viscosity, conductivity and Prandtl number of liquid water at a temperature (IAPWS-IF97).

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationPulp and paperFood, dairy and textileIAPWS-IF97 (water and steam)Deaerator and feedwater systemDesuperheater and PRDS

Inputs

Examples: Feedwater, 100 °CCooling water, 25 °CBoiler water, 250 °C

Results

Saturation pressure39.759bar
Specific enthalpy1,085.7kJ/kg
Specific entropy2.7934kJ/(kg·K)
Density798.89kg/m³
Specific volume0.001252m³/kg
Specific heat capacity4.8650kJ/(kg·K)
Dynamic viscosity1.0628e-04Pa·s
Kinematic viscosity1.3304e-07m²/s
Thermal conductivity0.61364W/(m·K)
Prandtl number0.84262
Latent heat of vaporisation1,715.3kJ/kg

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Feedwater, 100 °C. The inputs, in the units selected above:

InputValue
Water temperature100.00 °C

Applying the formula below gives:

ResultValue
Saturation pressure1.0142 bar
Specific enthalpy419.10 kJ/kg
Specific entropy1.3070 kJ/(kg·K)
Density958.35 kg/m³
Specific volume0.001043 m³/kg
Specific heat capacity4.2166 kJ/(kg·K)
Dynamic viscosity2.8159e-04 Pa·s
Kinematic viscosity2.9382e-07 m²/s
Thermal conductivity0.67722 W/(m·K)
Prandtl number1.7533
Latent heat of vaporisation2,256.5 kJ/kg

Open this example in the calculator and change any input.

Formula

Properties are evaluated from the IAPWS-IF97 equations, not from a fitted curve:

\(p_{sat} = p_s(T) \;\text{(IF97 Eq. 30)} \qquad h_f, s_f, v_f, c_p = f(p_{sat}, T) \;\text{(IF97 region 1)} \qquad h_{fg} = h_g - h_f\)

\(\nu = \frac{\mu}{\rho} \qquad Pr = \frac{c_p\,\mu}{k}\)

Variables

Symbol Meaning SI unit
\(T\) water temperature K
\(p_{sat}\) saturation (boiling) pressure at \(T\) Pa
\(h_f\) specific enthalpy of saturated liquid J/kg
\(s_f\) specific entropy of saturated liquid J/(kg·K)
\(\rho\) density kg/m³
\(v_f\) specific volume m³/kg
\(c_p\) isobaric specific heat capacity J/(kg·K)
\(\mu\) dynamic viscosity Pa·s
\(\nu\) kinematic viscosity m²/s
\(k\) thermal conductivity W/(m·K)
\(Pr\) Prandtl number –
\(h_{fg}\) latent heat of vaporisation J/kg

Method and standards

Thermodynamic properties from the IAPWS Industrial Formulation 1997 (region 1 and the region 4 saturation line; region 3 by iteration above 350 °C). Viscosity from the IAPWS 2008 formulation and thermal conductivity from the IAPWS 2011 formulation, both evaluated at the IF97 density. The code is FireCAD's own implementation, verified against the check values printed in the IAPWS releases.

Where it is used

  • Density and viscosity for pump and pipe calculations.
  • Enthalpy for heat balances of hot water and feedwater.
  • Specific heat and conductivity for heat-exchanger design.

Common mistakes

  • Using 1000 kg/m³ for hot water: at 150 °C it is about 917 kg/m³.
  • Ignoring pressure for hot water near boiling.
  • Mixing dynamic and kinematic viscosity.

Assumptions and limits

  • 0.01 °C to about 373.85 °C, just below the critical point (373.946 °C), where saturation properties are singular.
  • The thermal conductivity omits the critical enhancement term of the IAPWS 2011 formulation: it reads about 0.2 % low for hot liquid near 200 °C and increasingly low towards the critical point. Viscosity near the critical point is also less certain.
  • Pure water; dissolved solids change density and boiling point slightly.

References

  • IAPWS R7-97(2012) IF97
  • IAPWS R12-08 viscosity
  • IAPWS R15-11 thermal conductivity

Questions and answers

Is the water at its saturation pressure or at atmospheric pressure?

At its saturation pressure, i.e. on the boiling line. Below 100 °C the difference from atmospheric-pressure water is negligible for density, viscosity and heat capacity (well under 0.1 %).

Why does the Prandtl number fall so steeply with temperature?

Viscosity drops by a factor of six between 20 °C and 150 °C while conductivity and heat capacity change little, so Pr = cp·μ/k falls from about 7 to about 1.1.

Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.