Worked example
Example: Superheated steam, 10 bar / 250 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Absolute pressure | 10.000 bar |
| Temperature | 250.00 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| State | Superheated steam |
| Saturation temperature at p | 179.89 °C |
| Degree of superheat | 70.114 K |
| Specific enthalpy | 2,943.2 kJ/kg |
| Specific entropy | 6.9266 kJ/(kg·K) |
| Specific volume | 0.23274 m³/kg |
| Density | 4.2967 kg/m³ |
| Specific heat capacity | 2.2116 kJ/(kg·K) |
| Dynamic viscosity | 1.8058e-05 Pa·s |
| Kinematic viscosity | 4.2029e-06 m²/s |
| Thermal conductivity | 0.040456 W/(m·K) |
| Prandtl number | 0.98720 |
| Speed of sound | 550.11 m/s |
Open this example in the calculator and change any input.
Formula
The state is located in the IAPWS-IF97 regions and the properties follow from the Gibbs or Helmholtz free energy of that region:
\(\text{region 1, 2, 5:}\; g(p, T) \quad\Rightarrow\quad v = \left(\frac{\partial g}{\partial p}\right)_T,\; h = g - T\left(\frac{\partial g}{\partial T}\right)_p,\; s = -\left(\frac{\partial g}{\partial T}\right)_p,\; c_p = -T\left(\frac{\partial^2 g}{\partial T^2}\right)_p\)
\(\text{region 3:}\; f(\rho, T) \;\text{with}\; p(\rho, T) = p \;\text{solved for}\; \rho \qquad \Delta T_{sh} = T - T_{sat}(p) \qquad \nu = \mu / \rho \qquad Pr = c_p \mu / k\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(p\) | absolute pressure | Pa |
| \(T\) | temperature | K |
| \(\text{phase}\) | compressed liquid, superheated steam or supercritical fluid | – |
| \(T_{sat}\) | saturation temperature at \(p\) | K |
| \(\Delta T_{sh}\) | degree of superheat (vapour only) | K |
| \(h\) | specific enthalpy | J/kg |
| \(s\) | specific entropy | J/(kg·K) |
| \(v\) | specific volume | m³/kg |
| \(\rho\) | density | kg/m³ |
| \(c_p\) | isobaric specific heat capacity | J/(kg·K) |
| \(\mu\) | dynamic viscosity | Pa·s |
| \(\nu\) | kinematic viscosity | m²/s |
| \(k\) | thermal conductivity | W/(m·K) |
| \(Pr\) | Prandtl number | – |
| \(w\) | speed of sound | m/s |
Method and standards
FireCAD's own implementation of the IAPWS Industrial Formulation 1997 (IAPWS R7-97(2012)): regions 1, 2 and 5 from their Gibbs equations, region 3 from the Helmholtz equation with the density found by iteration, the saturation line from the region 4 equation. Transport properties from the IAPWS 2008 (viscosity) and 2011 (thermal conductivity) formulations at the IF97 density. Verified against the check values printed in the releases.
Where it is used
- Heat balances of boilers, turbines, heat exchangers and steam users.
- Steam pipe sizing (specific volume) and flow meter density compensation.
- Checking the condition of steam from measured pressure and temperature.
Common mistakes
- Entering gauge pressure where absolute pressure is needed.
- Using old steam tables (IFC-67) and newer IF97 values side by side: the differences are small but show up in tests.
- Reading saturated values when the steam is superheated, or the reverse.
Assumptions and limits
- 0 to 800 °C up to 1 000 bar, and 800 to 2 000 °C up to 500 bar (IF97 range). Above 800 °C the transport properties are extrapolations.
- The critical enhancement of viscosity and conductivity is omitted. It leaves the conductivity about 0.2 % low already for hot liquid near 200 °C and steam near 450 °C at 60–70 bar, and much more close to the critical point.
- Pressures are absolute. Enter gauge readings with a gauge unit (bar g, kg/cm² g, psig) and the page adds one standard atmosphere.
References
- IAPWS R7-97(2012) IF97
- IAPWS R12-08 viscosity
- IAPWS R15-11 thermal conductivity
Questions and answers
What is the degree of superheat?
The temperature above the saturation temperature at the same pressure, T − T_sat(p). Steam at 10 bar(a) and 250 °C is 70 K superheated because water boils at 179.9 °C at 10 bar.
What does "compressed liquid" mean?
Water below its boiling temperature at the given pressure. Its properties are close to those of saturated water at the same temperature, which is why older tables give only the saturated values.
What happens exactly at saturation?
On the saturation line the properties depend on the steam quality, not on pressure and temperature alone. The page then shows saturated-liquid properties with a warning; use the flash steam or saturated water calculators for wet steam.
Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.