FireCADCalc

Steam Consumption for Heating a Process Stream

Steam needed to heat a liquid stream from its flow, specific heat and temperature rise, with losses, using IF97 steam and condensate enthalpies.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationPulp and paperFood, dairy and textileIAPWS-IF97 (water and steam)Boiler operation engineer (BOE) examinations

Inputs

Examples: 10 t/h water 30 to 80 °C, 4 bar(a)Oil heater 8 bar(a), dry steam

Results

Steam and condensate enthalpies from IAPWS-IF97 at the steam pressure.

Heat supplied, product heat plus losses610.58kW
Heat given up per kg of steam2,296.8kJ/kg
Steam consumption957.00kg/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 10 t/h water 30 to 80 °C, 4 bar(a). The inputs, in the units selected above:

InputValue
Product flow10,000 kg/h
Product specific heat4.1868 kJ/(kg·K)
Product in30.000 °C
Product out80.000 °C
Steam pressure (absolute)4.0000 bar
Steam dryness fraction97.000 %
Condensate leaving temperature90.000 °C
Heat losses (share of useful heat)5.0000 %

Applying the formula below gives:

ResultValue
Heat supplied, product heat plus losses610.58 kW
Heat given up per kg of steam2,296.8 kJ/kg
Steam consumption957.00 kg/h

Open this example in the calculator and change any input.

Formula

\(\dot Q = \dot m_p c_p (T_2 - T_1)(1 + k_l), \quad \dot m_s = \frac{\dot Q}{h_{steam}(p, x) - h_{cond}(p, T_c)}\)

Variables

Symbol Meaning SI unit
\(\dot m_p\) Product flow kg/s
\(c_p\) Product specific heat J/(kg·K)
\(T_1\) Product in K
\(T_2\) Product out K
\(p_s\) Steam pressure (absolute) Pa
\(x\) Steam dryness fraction -
\(T_c\) Condensate leaving temperature K
\(k_l\) Heat losses (share of useful heat) -
\(\dot Q\) Heat supplied, product heat plus losses W
\(\Delta h\) Heat given up per kg of steam J/kg
\(\dot m_s\) Steam consumption kg/s

Method and standards

Energy balance.

Where it is used

  • Heat exchangers, jacketed vessels, process heaters.
  • BOE examinations.

Common mistakes

  • Latent heat only.
  • Forgetting losses.

Assumptions and limits

  • Steady flow.
  • Steam is wet or dry saturated at p_s (dryness x); superheated steam is not an option here (see the steam consumption from heat duty calculator).
  • The heat shown includes the loss allowance; the heat reaching the product is Q/(1 + k_l).
  • Condensate leaves between the product inlet temperature and the steam saturation temperature.

References

  • Energy balance ṁ_s = ṁ_p c_p ΔT (1 + k)/(h_steam − h_condensate); IAPWS-IF97

Questions and answers

10 t/h of water from 30 to 80 °C with 4 bar(a) steam?

About 610 kW with 5 % losses: roughly 950 kg/h of steam.

Why does condensate temperature matter?

Sub-cooling the condensate gives extra heat per kg.

Wet steam?

Lower dryness carries less latent heat; separators help.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.