Steam Consumption from Heat Duty

Steam flow a heater, exchanger or process needs for a given heat duty, from the steam and condensate enthalpies (IAPWS-IF97).

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationPulp and paperFood, dairy and textileIAPWS-IF97 (water and steam)

Inputs

Examples: Process heater 1 MW, 8 bar(a) dry saturatedHeat exchanger 2.5 MW, 12 bar(a) / 250 °C, condensate 10 K sub-cooledSteam tracing 50 kW, 4 bar(a) saturated, condensate 20 K sub-cooled

Absolute. Choose a gauge unit (bar g, psig) to enter gauge readings.
0 for condensate leaving as saturated liquid (steam trap at the outlet).

Results

Steam flow4,125.9kg/h
Saturation temperature at p187.96°C
Steam enthalpy2,935.7kJ/kg
Condensate enthalpy754.33kJ/kg
Heat given up per kg of steam2,181.4kJ/kg

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Process heater 1 MW, 8 bar(a) dry saturated. The inputs, in the units selected above:

InputValue
Heat duty1,000.0 kW
Steam pressure at the user (absolute)8.0000 bar
Steam conditionDry saturated
Steam temperature (superheated only)250.00 °C
Condensate sub-cooling below saturation0 K

Applying the formula below gives:

ResultValue
Steam flow1,758.4 kg/h
Saturation temperature at p170.41 °C
Steam enthalpy2,768.3 kJ/kg
Condensate enthalpy721.02 kJ/kg
Heat given up per kg of steam2,047.3 kJ/kg

Open this example in the calculator and change any input.

Formula

An energy balance on the steam side of the user:

\(\dot m_s = \frac{\dot Q}{\Delta h} \qquad \Delta h = h_s - h_c \qquad h_c = h(p,\; T_{sat} - \Delta T_{sc})\)

Variables

Symbol Meaning SI unit
\(\dot Q\) heat duty delivered by the steam W
\(p\) absolute steam pressure at the user Pa
\(\text{state}\) dry saturated, or superheated at \(T_s\) –
\(T_s\) steam temperature when superheated K
\(\Delta T_{sc}\) condensate sub-cooling below saturation K
\(\dot m_s\) steam flow kg/s
\(T_{sat}\) saturation temperature at \(p\) K
\(h_s\) steam enthalpy J/kg
\(h_c\) condensate enthalpy J/kg
\(\Delta h\) heat given up per kg of steam J/kg

Method and standards

Steam and condensate enthalpies from FireCAD's IAPWS-IF97 implementation: region 2 for superheated steam (region 3 close to the critical point), the saturation line for dry saturated steam, region 1 for the condensate at the steam pressure.

Where it is used

  • Sizing steam supply to heaters, reboilers, dryers and jackets.
  • Steam balances of process plants.
  • Choosing steam pressure for a heating duty.

Common mistakes

  • Using the latent heat at the wrong pressure.
  • Forgetting that superheat adds little to heating but harms heat transfer.
  • Leaving out heat losses and start-up loads.

Assumptions and limits

  • Steady state; no heat lost from the equipment to the surroundings.
  • Condensate leaves at the steam pressure; the sub-cooling is relative to the saturation temperature at that pressure.
  • Wet steam (dryness below 1) is not an input; it gives up less heat per kg.

References

  • IAPWS R7-97(2012) IF97

Questions and answers

How much steam does 1 MW of heating need?

With dry saturated steam at 8 bar(a) and condensate leaving saturated, each kg gives up 2 047 kJ, so 1 MW needs 0.488 kg/s, about 1 760 kg/h.

Does superheat help?

A little. Superheat adds sensible heat per kg (12 bar(a) at 250 °C gives 2 181 kJ/kg to 10 K sub-cooled condensate), but most users want saturated steam because condensing gives a steady, high heat-transfer coefficient.

Should I add a margin?

The result is the theoretical steam for the stated duty. Add distribution losses, start-up loads and any heat losses from the equipment separately.

Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.