Worked example
Example: Process heater 1 MW, 8 bar(a) dry saturated. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Heat duty | 1,000.0 kW |
| Steam pressure at the user (absolute) | 8.0000 bar |
| Steam condition | Dry saturated |
| Steam temperature (superheated only) | 250.00 °C |
| Condensate sub-cooling below saturation | 0 K |
Applying the formula below gives:
| Result | Value |
|---|---|
| Steam flow | 1,758.4 kg/h |
| Saturation temperature at p | 170.41 °C |
| Steam enthalpy | 2,768.3 kJ/kg |
| Condensate enthalpy | 721.02 kJ/kg |
| Heat given up per kg of steam | 2,047.3 kJ/kg |
Open this example in the calculator and change any input.
Formula
An energy balance on the steam side of the user:
\(\dot m_s = \frac{\dot Q}{\Delta h} \qquad \Delta h = h_s - h_c \qquad h_c = h(p,\; T_{sat} - \Delta T_{sc})\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot Q\) | heat duty delivered by the steam | W |
| \(p\) | absolute steam pressure at the user | Pa |
| \(\text{state}\) | dry saturated, or superheated at \(T_s\) | – |
| \(T_s\) | steam temperature when superheated | K |
| \(\Delta T_{sc}\) | condensate sub-cooling below saturation | K |
| \(\dot m_s\) | steam flow | kg/s |
| \(T_{sat}\) | saturation temperature at \(p\) | K |
| \(h_s\) | steam enthalpy | J/kg |
| \(h_c\) | condensate enthalpy | J/kg |
| \(\Delta h\) | heat given up per kg of steam | J/kg |
Method and standards
Steam and condensate enthalpies from FireCAD's IAPWS-IF97 implementation: region 2 for superheated steam (region 3 close to the critical point), the saturation line for dry saturated steam, region 1 for the condensate at the steam pressure.
Where it is used
- Sizing steam supply to heaters, reboilers, dryers and jackets.
- Steam balances of process plants.
- Choosing steam pressure for a heating duty.
Common mistakes
- Using the latent heat at the wrong pressure.
- Forgetting that superheat adds little to heating but harms heat transfer.
- Leaving out heat losses and start-up loads.
Assumptions and limits
- Steady state; no heat lost from the equipment to the surroundings.
- Condensate leaves at the steam pressure; the sub-cooling is relative to the saturation temperature at that pressure.
- Wet steam (dryness below 1) is not an input; it gives up less heat per kg.
References
- IAPWS R7-97(2012) IF97
Questions and answers
How much steam does 1 MW of heating need?
With dry saturated steam at 8 bar(a) and condensate leaving saturated, each kg gives up 2 047 kJ, so 1 MW needs 0.488 kg/s, about 1 760 kg/h.
Does superheat help?
A little. Superheat adds sensible heat per kg (12 bar(a) at 250 °C gives 2 181 kJ/kg to 10 K sub-cooled condensate), but most users want saturated steam because condensing gives a steady, high heat-transfer coefficient.
Should I add a margin?
The result is the theoretical steam for the stated duty. Add distribution losses, start-up loads and any heat losses from the equipment separately.
Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.