Steam Accumulator Storage Capacity (Ruths)

Steam a Ruths steam accumulator releases when its pressure falls from charging to discharge pressure, from its volume and water filling (IAPWS-IF97).

Process steam and utilitiesSugar mill and cogenerationPulp and paperFood, dairy and textileIAPWS-IF97 (water and steam)BoilerTank and drum

Inputs

Examples: 100 m³, 90 % water, 16 to 6 bar(a)30 m³, 85 %, 12 to 4 bar(a)200 m³, 90 %, 25 to 10 bar(a)

Results

The water swells as it heats during charging; the filling must leave steam space for it and for separation.

Steam released2,010.5kg
Steam released per m³ of accumulator volume67.016kg/m³
Water held at charge22.398t
Share of the charged water released as steam8.9763%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 100 m³, 90 % water, 16 to 6 bar(a). The inputs, in the units selected above:

InputValue
Accumulator volume100.00 m³
Water filling at charge, share of volume90.000 %
Charging pressure (absolute)16.000 bar
Discharge (minimum) pressure (absolute)6.0000 bar

Applying the formula below gives:

ResultValue
Steam released6,936.3 kg
Steam released per m³ of accumulator volume69.363 kg/m³
Water held at charge77.675 t
Share of the charged water released as steam8.9299 %

Open this example in the calculator and change any input.

Formula

\(m_w = \phi\,V\,\rho_f(p_1) \qquad \frac{dm}{m} = \frac{dh_f}{h_{fg}} \qquad x = 1 - \exp\left(-\int_{T_2}^{T_1} \frac{dh_f}{h_{fg}}\right) \qquad m_s = m_w\,x\)

Variables

Symbol Meaning SI unit
\(V\) accumulator volume m³
\(\phi\) water filling at charge –
\(p_1\) charging pressure Pa
\(p_2\) discharge pressure Pa
\(m_s\) steam released kg
\(m_s/V\) steam released per m³ of accumulator volume (not a density) kg/m³
\(m_w\) water at charge kg
\(x\) share of the charged water released as steam –
\(m\) water left in the vessel during discharge kg
\(T_1\), \(T_2\) saturation temperatures at \(p_1\) and \(p_2\) K
\(\rho_f\) saturated water density (IF97) kg/m³
\(h_f, h_{fg}\) saturated liquid enthalpy and latent heat (IF97) J/kg

Method and standards

Saturated water flashing as the pressure falls from charging to discharge pressure (Ruths principle). The steam leaves as it forms, so the energy balance of the water left, d(m h_f) = h_g dm, gives dm/m = dh_f/h_fg; it is integrated over the saturation temperature with FireCAD's IAPWS-IF97.

Where it is used

  • Peak-load steam supply in process plants.
  • Smoothing boiler firing for batch users.
  • Storing excess steam from waste heat.

Common mistakes

  • Using the whole vessel volume as water.
  • Ignoring the steam space needed for swelling during charging.
  • Forgetting that the outlet needs a pressure reducing valve.

Assumptions and limits

  • Water saturated at charging pressure; no heat loss; steam leaves dry.
  • Gradual discharge with the steam leaving as it forms; this gives about 1 % less than a single-step flash of the whole charge at the discharge pressure. The steam already in the steam space at charge is not counted.
  • The filling is the share at charge (after the water has swelled); leave steam space above it for separation.

References

  • Flash of saturated water between two pressures (Ruths principle)
  • IAPWS R7-97 IF97

Questions and answers

How much steam does an accumulator store?

A 100 m³ accumulator 90 % full of water charged to 16 bar(a) and drawn down to 6 bar(a) releases 6.9 t of steam, 69 kg per m³: 8.9 % of the 77.7 t of water.

Why use one?

It supplies short peaks (autoclaves, batch processes, soot blowers) so the boiler can fire steadily.

How do I get more storage?

A wider pressure swing: charge higher or let the users accept a lower minimum pressure.

Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.