Worked example
Example: 10 kg/cm² g, 0.5 kg separated, 10 kg condensate, 1.013 bar at 115 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Steam pressure in the main (absolute) | 9.8066 bar g |
| Water collected in the separator | 0.50000 kg |
| Condensate from the throttling calorimeter | 10.000 kg |
| Pressure after throttling (absolute) | 1.0132 bar |
| Temperature after throttling | 115.00 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Dryness from the separator x₁ = m_c / (m_c + m_w) | 95.238 % |
| Dryness from the throttling calorimeter | 96.318 % |
| Dryness fraction of the steam x = x₁ x₂ | 91.731 % |
| Enthalpy of the steam in the main | 2,614.5 kJ/kg |
| Superheat after throttling | 15.026 K |
Open this example in the calculator and change any input.
Formula
\(x_1 = \frac{m_c}{m_c + m_w}\)
\(h_{f1} + x_2\, h_{fg1} = h(p_2, T_2)\)
\(x = x_1\, x_2, \quad h = h_{f1} + x\, h_{fg1}, \quad \Delta T_{sh} = T_2 - T_{sat}(p_2)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(p_1\) | Steam pressure in the main (absolute) | Pa |
| \(m_w\) | Water collected in the separator | kg |
| \(m_c\) | Condensate from the throttling calorimeter | kg |
| \(p_2\) | Pressure after throttling (absolute) | Pa |
| \(T_2\) | Temperature after throttling | K |
| \(x_1\) | Dryness from the separator x₁ = m_c / (m_c + m_w) | - |
| \(x_2\) | Dryness from the throttling calorimeter | - |
| \(x\) | Dryness fraction of the steam x = x₁ x₂ | - |
| \(h\) | Enthalpy of the steam in the main | J/kg |
| \(\Delta T_{sh}\) | Superheat after throttling | K |
| \(h_{f1}\), \(h_{fg1}\) | saturated liquid enthalpy and latent heat at the main pressure | J/kg |
| \(T_{sat}(p_2)\) | saturation temperature after throttling | K |
Method and standards
Separator mass balance, then throttling at constant enthalpy into the superheated region; IAPWS-IF97 properties at the main and calorimeter states.
Worked example
Steam at 10 kg/cm² g: 0.5 kg of water is separated and 10 kg of condensate collected; after throttling the steam is at 1.013 bar and 115 °C.
- x₁ = 10 / 10.5 = 0.952
- h at 1.013 bar, 115 °C = 2706.3 kJ/kg; at 10.82 bar h_f = 778.0, h_fg = 2002.1 kJ/kg; x₂ = (2706.3 − 778.0)/2002.1 = 0.963
- x = 0.952 × 0.963 = 0.917
Where it is used
- Boiler attendant and operator examinations.
- Measuring steam quality from boilers and in mains.
Common mistakes
- Using the separator's dryness alone.
- Using gauge pressure after the throttle.
- Accepting a reading with almost no superheat (error grows).
Assumptions and limits
- At least about 5 K of superheat after the throttle; a warning is given below that.
- Heat loss from the calorimeter neglected; the pressure drop across the separator is neglected (the throttle inlet is taken at the main pressure).
- x₂ above 1 is reported with a warning (the steam leaving the separator was superheated, or a reading is wrong).
- The main pressure may be entered as gauge (converted with the standard atmosphere, 101.325 kPa); the pressure after throttling is absolute.
References
- IAPWS-IF97 (water and steam)
- Throttling at constant enthalpy (textbook)
Questions and answers
What dryness for 0.5 kg separated, 10 kg condensate, throttled to 1.013 bar at 115 °C from 10 kg/cm² g?
x₁ = 0.952 from the separator, x₂ = 0.963 from the throttling, so x = 0.917.
Why throttle the steam?
Throttling keeps the enthalpy constant. When the steam leaves superheated, its measured pressure and temperature fix that enthalpy, and so the dryness before the valve.
What if the throttled steam is not superheated?
Then its state is unknown from p and T: the steam was too wet, which is why the separator comes first.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.