Worked example
Example: 8 kg/cm² g: 0.4 kg water, 8 kg condensate. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Steam pressure in the main (absolute) | 7.8453 bar g |
| Water collected in the separator | 0.40000 kg |
| Steam condensed after the separator | 8.0000 kg |
Applying the formula below gives:
| Result | Value |
|---|---|
| Dryness fraction x = m_c / (m_c + m_w) | 95.238 % |
| Wetness fraction | 4.7619 % |
| Enthalpy of the steam in the main | 2,675.6 kJ/kg |
| Saturation temperature | 174.69 °C |
Open this example in the calculator and change any input.
Formula
\(x = \frac{m_c}{m_c + m_w}\)
\(h = h_f + x\, h_{fg}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(p\) | Steam pressure in the main (absolute) | Pa |
| \(m_w\) | Water collected in the separator | kg |
| \(m_c\) | Steam condensed after the separator | kg |
| \(x\) | Dryness fraction x = m_c / (m_c + m_w) | - |
| \(1 - x\) | Wetness fraction | - |
| \(h\) | Enthalpy of the steam in the main | J/kg |
| \(T_s\) | Saturation temperature | K |
Method and standards
Mass balance on the separator: the condensate is the dry steam passed, the water collected is the moisture removed. Saturation properties from IAPWS-IF97.
Worked example
In a test at 8 kg/cm² g, 0.4 kg of water is collected in the separator while 8 kg of steam condensate is collected.
- x = 8 / (8 + 0.4) = 0.952
- At 8.86 bar absolute: h_f = 739.8 kJ/kg, h_fg = 2032.6 kJ/kg; h = 739.8 + 0.952 × 2032.6 = 2675.6 kJ/kg
Where it is used
- Boiler attendant examinations.
- Checking boiler steam quality and carry-over.
- Laboratory steam tests.
Common mistakes
- Swapping the two masses.
- Collecting the two masses over different times.
- Taking the result as exact: real separators miss some water.
Assumptions and limits
- The separator efficiency is taken as 100 %.
- Masses collected over the same period.
References
- IAPWS-IF97 (water and steam)
- Separating calorimeter mass balance (textbook)
Questions and answers
What dryness gives 0.4 kg of water and 8 kg of condensate?
x = 8 / (8 + 0.4) = 0.952. At 8 kg/cm² g the steam then holds 2676 kJ/kg.
Why is the separating calorimeter result too high?
The separator never catches every droplet; some water passes on with the steam and is counted as dry.
When is a throttling calorimeter added?
When the steam is very wet: the separator removes most water, then the throttling calorimeter measures the dryness of what is left.