FireCADCalc

Separating Calorimeter Dryness Fraction

Dryness fraction of wet steam from a separating calorimeter: the water separated and the dry steam condensed in the same time, with the enthalpy of the sample steam.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationPulp and paperFood, dairy and textileIAPWS-IF97 (water and steam)BoilerBoiler attendant and boiler operator examinations

Inputs

Examples: 8 kg/cm² g: 0.4 kg water, 8 kg condensate10 bar g: 1.2 kg, 18 kg5 bar(a): no water separated

Results

A separator never removes all the water, so this dryness fraction is a little high; for very wet steam follow it with a throttling calorimeter.

Dryness fraction x = m_c / (m_c + m_w)93.750%
Wetness fraction6.2500%
Enthalpy of the steam in the main2,655.8kJ/kg
Saturation temperature184.12°C

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 8 kg/cm² g: 0.4 kg water, 8 kg condensate. The inputs, in the units selected above:

InputValue
Steam pressure in the main (absolute)7.8453 bar g
Water collected in the separator0.40000 kg
Steam condensed after the separator8.0000 kg

Applying the formula below gives:

ResultValue
Dryness fraction x = m_c / (m_c + m_w)95.238 %
Wetness fraction4.7619 %
Enthalpy of the steam in the main2,675.6 kJ/kg
Saturation temperature174.69 °C

Open this example in the calculator and change any input.

Formula

\(x = \frac{m_c}{m_c + m_w}\)

\(h = h_f + x\, h_{fg}\)

Variables

Symbol Meaning SI unit
\(p\) Steam pressure in the main (absolute) Pa
\(m_w\) Water collected in the separator kg
\(m_c\) Steam condensed after the separator kg
\(x\) Dryness fraction x = m_c / (m_c + m_w) -
\(1 - x\) Wetness fraction -
\(h\) Enthalpy of the steam in the main J/kg
\(T_s\) Saturation temperature K

Method and standards

Mass balance on the separator: the condensate is the dry steam passed, the water collected is the moisture removed. Saturation properties from IAPWS-IF97.

Worked example

In a test at 8 kg/cm² g, 0.4 kg of water is collected in the separator while 8 kg of steam condensate is collected.

  • x = 8 / (8 + 0.4) = 0.952
  • At 8.86 bar absolute: h_f = 739.8 kJ/kg, h_fg = 2032.6 kJ/kg; h = 739.8 + 0.952 × 2032.6 = 2675.6 kJ/kg

Where it is used

  • Boiler attendant examinations.
  • Checking boiler steam quality and carry-over.
  • Laboratory steam tests.

Common mistakes

  • Swapping the two masses.
  • Collecting the two masses over different times.
  • Taking the result as exact: real separators miss some water.

Assumptions and limits

  • The separator efficiency is taken as 100 %.
  • Masses collected over the same period.

References

  • IAPWS-IF97 (water and steam)
  • Separating calorimeter mass balance (textbook)

Questions and answers

What dryness gives 0.4 kg of water and 8 kg of condensate?

x = 8 / (8 + 0.4) = 0.952. At 8 kg/cm² g the steam then holds 2676 kJ/kg.

Why is the separating calorimeter result too high?

The separator never catches every droplet; some water passes on with the steam and is counted as dry.

When is a throttling calorimeter added?

When the steam is very wet: the separator removes most water, then the throttling calorimeter measures the dryness of what is left.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.