FireCADCalc

Saturation Temperature and Pressure of Steam

Boiling temperature at a pressure or saturation pressure at a temperature, with liquid and vapour enthalpy, latent heat, entropy and specific volume (IAPWS-IF97).

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationPulp and paperFood, dairy and textileIAPWS-IF97 (water and steam)Desuperheater and PRDSFlash vessel and condensateBoiler attendant and boiler operator examinations

Inputs

Examples: Saturation at 10 bar(a)Saturation at 180 °CSaturation at 100 bar(a)Saturation at 1 atm

Pressure

Absolute. Choose a gauge unit (bar g, psig) to enter gauge readings.

Temperature

Results

Saturation pressure10.000bar
Saturation temperature179.89°C
Saturated liquid enthalpy762.68kJ/kg
Saturated vapour enthalpy2,777.1kJ/kg
Latent heat of vaporisation2,014.4kJ/kg
Saturated liquid entropy2.1384kJ/(kg·K)
Saturated vapour entropy6.5850kJ/(kg·K)
Saturated liquid specific volume0.001127m³/kg
Saturated vapour specific volume0.19435m³/kg

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Saturation at 10 bar(a). The inputs, in the units selected above:

InputValue
Look up byPressure
Pressure (absolute)10.000 bar
Temperature180.00 °C

Applying the formula below gives:

ResultValue
Saturation pressure10.000 bar
Saturation temperature179.89 °C
Saturated liquid enthalpy762.68 kJ/kg
Saturated vapour enthalpy2,777.1 kJ/kg
Latent heat of vaporisation2,014.4 kJ/kg
Saturated liquid entropy2.1384 kJ/(kg·K)
Saturated vapour entropy6.5850 kJ/(kg·K)
Saturated liquid specific volume0.001127 m³/kg
Saturated vapour specific volume0.19435 m³/kg

Open this example in the calculator and change any input.

Formula

On the saturation line the pressure and temperature are linked by the IAPWS-IF97 region 4 equation; the liquid and vapour properties come from the region 1 and region 2 equations at that state:

\(T_{sat} = T_{sat}(p) \quad\text{or}\quad p_{sat} = p_{sat}(T) \qquad h_{fg} = h_g - h_f\)

Variables

Symbol Meaning SI unit
\(\text{mode}\) look up by pressure or by temperature –
\(p\) absolute pressure entered Pa
\(T\) temperature entered K
\(p_{sat}\) saturation pressure Pa
\(T_{sat}\) saturation (boiling) temperature K
\(h_f\) saturated liquid enthalpy J/kg
\(h_g\) saturated vapour enthalpy J/kg
\(h_{fg}\) latent heat of vaporisation J/kg
\(s_f\) saturated liquid entropy J/(kg·K)
\(s_g\) saturated vapour entropy J/(kg·K)
\(v_f\) saturated liquid specific volume m³/kg
\(v_g\) saturated vapour specific volume m³/kg

Method and standards

IAPWS R7-97(2012), the Industrial Formulation 1997: region 4 saturation equation for \(p_{sat}(T)\) and its inverse \(T_{sat}(p)\); region 1 for the liquid and region 2 for the vapour up to 350 °C, and region 3 (by iteration on density) from 350 °C to the critical point. Enthalpy and entropy are referenced to the triple-point liquid, as in every IF97 steam table.

Where it is used

  • Reading steam temperature from a pressure gauge, or the reverse.
  • Setting condensate, flash and deaerator conditions.
  • Checking whether steam is superheated from its measured temperature.

Common mistakes

  • Using gauge pressure as absolute.
  • Assuming a measured temperature above saturation means dry steam everywhere in the line.
  • Forgetting the barometric pressure at high-altitude sites.

Assumptions and limits

  • Pure water; dissolved solids raise the boiling point slightly.
  • Valid from the triple point (0.01 °C, 611.657 Pa) to the critical point (373.946 °C, 220.64 bar).
  • Pressure is absolute.

References

  • IAPWS R7-97(2012) IF97

Questions and answers

At what temperature does water boil at 10 bar?

At 10 bar absolute the saturation temperature is 179.89 °C (453.04 K). At 10 bar gauge (11.01 bar absolute) it is about 184 °C, so check whether a reading is gauge or absolute.

Why does the latent heat fall as pressure rises?

The liquid and vapour become more alike as the critical point (220.64 bar, 373.95 °C) is approached. At 1 atm h_fg is 2 257 kJ/kg; at 100 bar it is 1 318 kJ/kg; at the critical point it is zero.

Which pressure should I enter for a boiler drum?

The absolute drum pressure. Choose a gauge unit (bar g, kg/cm² g, psig) to type a gauge reading; the calculator adds one standard atmosphere.

Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.