State of the steam when two flows at the same pressure mix without heat loss: the mixed enthalpy, and its dryness fraction or superheated temperature (IAPWS-IF97).

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationPulp and paperFood, dairy and textileIAPWS-IF97 (water and steam)BoilerDesuperheater and PRDSBoiler attendant and boiler operator examinations

Inputs

Examples: 10 bar g: 2 t/h at x 0.9 with 3 t/h at 250 °C10 bar g: 3 t/h at x 0.95 with 1 t/h dry20 bar(a): 4 t/h at 300 °C with 1 t/h at x 0.98

Stream 1

Stream 2

Results

Adiabatic mixing at constant pressure: the mixed enthalpy is the flow-weighted mean; no heat is lost and no pressure drops.

Enthalpy of stream 12,680.7kJ/kg
Enthalpy of stream 22,780.7kJ/kg
Enthalpy of the mixture2,705.7kJ/kg
Dryness fraction of the mixture (1 when superheated)96.250%
Temperature of the mixture184.12°C
Superheat of the mixture (0 when wet)0K

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 10 bar g: 2 t/h at x 0.9 with 3 t/h at 250 °C. The inputs, in the units selected above:

InputValue
Pressure of both streams and the mixture (absolute)10.000 bar g
Flow of stream 12,000.0 kg/h
State of stream 1Wet or dry saturated, at the dryness below
Dryness fraction of stream 190.000 %
Temperature of stream 1 (superheated)250.00 °C
Flow of stream 23,000.0 kg/h
State of stream 2Superheated, at the temperature below
Dryness fraction of stream 2100.00 %
Temperature of stream 2 (superheated)250.00 °C

Applying the formula below gives:

ResultValue
Enthalpy of stream 12,580.8 kJ/kg
Enthalpy of stream 22,939.4 kJ/kg
Enthalpy of the mixture2,796.0 kJ/kg
Dryness fraction of the mixture (1 when superheated)100.00 %
Temperature of the mixture189.78 °C
Superheat of the mixture (0 when wet)5.6544 K

Open this example in the calculator and change any input.

Formula

\(h_m = \frac{\dot m_1 h_1 + \dot m_2 h_2}{\dot m_1 + \dot m_2}\)

\(x_m = \frac{h_m - h_f}{h_{fg}}\ (h_m \le h_g), \qquad T_m = T(p, h_m)\ (h_m > h_g)\)

Variables

Symbol Meaning SI unit
\(p\) Pressure of both streams and the mixture (absolute) Pa
\(\dot m_1\) Flow of stream 1 kg/s
\(\text{state}_1\) State of stream 1 -
\(x_1\) Dryness fraction of stream 1 -
\(T_1\) Temperature of stream 1 (superheated) K
\(\dot m_2\) Flow of stream 2 kg/s
\(\text{state}_2\) State of stream 2 -
\(x_2\) Dryness fraction of stream 2 -
\(T_2\) Temperature of stream 2 (superheated) K
\(h_1\) Enthalpy of stream 1 J/kg
\(h_2\) Enthalpy of stream 2 J/kg
\(h_m\) Enthalpy of the mixture J/kg
\(x_m\) Dryness fraction of the mixture (1 when superheated) -
\(T_m\) Temperature of the mixture K
\(\Delta T_{sh}\) Superheat of the mixture (0 when wet) K

Method and standards

Steady adiabatic mixing at constant pressure (energy balance). Each stream's enthalpy and the mixed state from IAPWS-IF97.

Worked example

2 t/h of steam at dryness 0.9 and 3 t/h at 250 °C meet in a header at 10 bar g.

  • h₁ = 781.4 + 0.9 × 1999.3 = 2580.8 kJ/kg; h₂ = 2939.4 kJ/kg (superheated)
  • h_m = (2 × 2580.8 + 3 × 2939.4)/5 = 2796.0 kJ/kg, above h_g = 2780.7 kJ/kg
  • The mixture is superheated: 189.8 °C, 5.7 K above saturation

Where it is used

  • Boiler examinations: steam from two boilers into one header.
  • Wet and superheated steam meeting in a header.
  • Checking whether a mixed header stays superheated.

Common mistakes

  • Averaging temperatures instead of enthalpies.
  • Mixing streams at different pressures without allowing for the throttling.
  • Forgetting the flows' weighting.

Assumptions and limits

  • Both streams and the mixture at one pressure. A stream from a higher-pressure line is throttled into the header at constant enthalpy: find its enthalpy at its own pressure (steam property calculators) and enter the state at the header pressure that has the same enthalpy.
  • A superheated stream must be entered as superheated with its temperature; "dry saturated" at dryness 1 gives h_g, not the superheated enthalpy.
  • No heat loss; no water drained.

References

  • IAPWS-IF97 (water and steam)

Questions and answers

What comes out of mixing 2 t/h at dryness 0.9 with 3 t/h at 250 °C, both at 10 bar g?

The mix holds 2796 kJ/kg, just above dry saturated: it is superheated by 5.7 K at 189.8 °C.

And 3 t/h at dryness 0.95 with 1 t/h dry?

Dryness 0.9625: the flow-weighted mean of the two dryness fractions, since both are wet at the same pressure.

Why mix by enthalpy and not temperature?

Wet steam at one pressure has one temperature whatever its dryness; only the enthalpy tells how much water it holds.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.