Worked example
Example: 10 bar g: 2 t/h at x 0.9 with 3 t/h at 250 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Pressure of both streams and the mixture (absolute) | 10.000 bar g |
| Flow of stream 1 | 2,000.0 kg/h |
| State of stream 1 | Wet or dry saturated, at the dryness below |
| Dryness fraction of stream 1 | 90.000 % |
| Temperature of stream 1 (superheated) | 250.00 °C |
| Flow of stream 2 | 3,000.0 kg/h |
| State of stream 2 | Superheated, at the temperature below |
| Dryness fraction of stream 2 | 100.00 % |
| Temperature of stream 2 (superheated) | 250.00 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Enthalpy of stream 1 | 2,580.8 kJ/kg |
| Enthalpy of stream 2 | 2,939.4 kJ/kg |
| Enthalpy of the mixture | 2,796.0 kJ/kg |
| Dryness fraction of the mixture (1 when superheated) | 100.00 % |
| Temperature of the mixture | 189.78 °C |
| Superheat of the mixture (0 when wet) | 5.6544 K |
Open this example in the calculator and change any input.
Formula
\(h_m = \frac{\dot m_1 h_1 + \dot m_2 h_2}{\dot m_1 + \dot m_2}\)
\(x_m = \frac{h_m - h_f}{h_{fg}}\ (h_m \le h_g), \qquad T_m = T(p, h_m)\ (h_m > h_g)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(p\) | Pressure of both streams and the mixture (absolute) | Pa |
| \(\dot m_1\) | Flow of stream 1 | kg/s |
| \(\text{state}_1\) | State of stream 1 | - |
| \(x_1\) | Dryness fraction of stream 1 | - |
| \(T_1\) | Temperature of stream 1 (superheated) | K |
| \(\dot m_2\) | Flow of stream 2 | kg/s |
| \(\text{state}_2\) | State of stream 2 | - |
| \(x_2\) | Dryness fraction of stream 2 | - |
| \(T_2\) | Temperature of stream 2 (superheated) | K |
| \(h_1\) | Enthalpy of stream 1 | J/kg |
| \(h_2\) | Enthalpy of stream 2 | J/kg |
| \(h_m\) | Enthalpy of the mixture | J/kg |
| \(x_m\) | Dryness fraction of the mixture (1 when superheated) | - |
| \(T_m\) | Temperature of the mixture | K |
| \(\Delta T_{sh}\) | Superheat of the mixture (0 when wet) | K |
Method and standards
Steady adiabatic mixing at constant pressure (energy balance). Each stream's enthalpy and the mixed state from IAPWS-IF97.
Worked example
2 t/h of steam at dryness 0.9 and 3 t/h at 250 °C meet in a header at 10 bar g.
- h₁ = 781.4 + 0.9 × 1999.3 = 2580.8 kJ/kg; h₂ = 2939.4 kJ/kg (superheated)
- h_m = (2 × 2580.8 + 3 × 2939.4)/5 = 2796.0 kJ/kg, above h_g = 2780.7 kJ/kg
- The mixture is superheated: 189.8 °C, 5.7 K above saturation
Where it is used
- Boiler examinations: steam from two boilers into one header.
- Wet and superheated steam meeting in a header.
- Checking whether a mixed header stays superheated.
Common mistakes
- Averaging temperatures instead of enthalpies.
- Mixing streams at different pressures without allowing for the throttling.
- Forgetting the flows' weighting.
Assumptions and limits
- Both streams and the mixture at one pressure. A stream from a higher-pressure line is throttled into the header at constant enthalpy: find its enthalpy at its own pressure (steam property calculators) and enter the state at the header pressure that has the same enthalpy.
- A superheated stream must be entered as superheated with its temperature; "dry saturated" at dryness 1 gives h_g, not the superheated enthalpy.
- No heat loss; no water drained.
References
- IAPWS-IF97 (water and steam)
Questions and answers
What comes out of mixing 2 t/h at dryness 0.9 with 3 t/h at 250 °C, both at 10 bar g?
The mix holds 2796 kJ/kg, just above dry saturated: it is superheated by 5.7 K at 189.8 °C.
And 3 t/h at dryness 0.95 with 1 t/h dry?
Dryness 0.9625: the flow-weighted mean of the two dryness fractions, since both are wet at the same pressure.
Why mix by enthalpy and not temperature?
Wet steam at one pressure has one temperature whatever its dryness; only the enthalpy tells how much water it holds.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.