Feed Tank Temperature from Condensate and Make-up

Temperature of boiler feedwater when returned condensate and cold make-up water mix in the feed tank, by an enthalpy balance (IAPWS-IF97).

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationPulp and paperFood, dairy and textileIAPWS-IF97 (water and steam)BoilerDeaerator and feedwater systemTank and drum

Inputs

Examples: 6 t/h condensate at 85 °C, 4 t/h make-up at 30 °C, open tankProcess plant: 15 t/h at 90 °C, 5 t/h at 25 °CPoor return: 2 t/h at 70 °C, 8 t/h at 28 °C

Results

Feedwater temperature73.796°C
Condensate share of the feedwater75.000%
Feedwater flow20,000kg/h
Mixed enthalpy308.98kJ/kg

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 6 t/h condensate at 85 °C, 4 t/h make-up at 30 °C, open tank. The inputs, in the units selected above:

InputValue
Condensate return flow6,000.0 kg/h
Condensate temperature85.000 °C
Make-up water flow4,000.0 kg/h
Make-up water temperature30.000 °C
Feed tank pressure (absolute)1.0132 bar

Applying the formula below gives:

ResultValue
Feedwater temperature63.036 °C
Condensate share of the feedwater60.000 %
Feedwater flow10,000 kg/h
Mixed enthalpy263.92 kJ/kg

Open this example in the calculator and change any input.

Formula

\(h_m = \frac{\dot m_c\,h(T_c) + \dot m_{mu}\,h(T_{mu})}{\dot m_c + \dot m_{mu}} \qquad T_m = T(p, h_m) \quad \text{(all enthalpies at the tank pressure } p\text{)} \qquad r_c = \frac{\dot m_c}{\dot m_c + \dot m_{mu}}\)

Variables

Symbol Meaning SI unit
\(\dot m_c\) condensate return flow kg/s
\(T_c\) condensate temperature K
\(\dot m_{mu}\) make-up water flow kg/s
\(T_{mu}\) make-up temperature K
\(p\) feed tank pressure, absolute Pa
\(T_m\) feedwater temperature K
\(r_c\) condensate share –
\(\dot m_{fw}\) feedwater flow, \(\dot m_c + \dot m_{mu}\) kg/s
\(h_m\) mixed enthalpy J/kg
\(h\) water enthalpy (IF97) J/kg

Method and standards

Adiabatic mixing; enthalpies and the outlet temperature from FireCAD's IAPWS-IF97.

Where it is used

  • Estimating feed tank temperature for pump NPSH and oxygen removal.
  • Valuing condensate return.
  • Checking a feed tank heater duty.

Common mistakes

  • Averaging temperatures without weighting by flow.
  • Ignoring flash losses from hot condensate.
  • Forgetting tank heat loss in winter.

Assumptions and limits

  • No heat loss or steam heating in the tank; condensate taken as liquid at tank pressure. Condensate arriving from a higher line pressure is entered at its temperature in the tank; any flash is lost through the vent.

References

  • IAPWS R7-97(2012) IF97
  • first law of thermodynamics

Questions and answers

What temperature does the feed tank reach?

The flow-weighted enthalpy of the two streams. 6 t/h of condensate at 85 °C and 4 t/h of make-up at 30 °C mix to 63.0 °C.

How can I raise it?

Return more condensate, recover flash steam and blowdown heat to the tank, or heat it with exhaust or low-pressure steam. Each 6 K or so of feedwater temperature saves roughly 1 % of fuel in a typical shell boiler; the feedwater temperature saving calculator works it out for your case.

What if the condensate is above 100 °C?

It flashes in an open tank; the flash steam leaves through the vent. Enter it at the tank's boiling point and recover the flash separately.

Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators