FireCADCalc

Deaerator and Feed Water Tank Sizing

Storage volume and total volume of a deaerator storage tank or feed water tank for a feed flow and storage time, with the length for a chosen diameter.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationPulp and paperFood, dairy and textileIAPWS-IF97 (water and steam)BoilerDeaerator and feedwater systemTank and drum

Inputs

Examples: 50 t/h, 10 min, deaerator 1.2 bar(a), 70 % usable, 2.4 m diameter300 t/h, 15 min, 6 bar(a), 60 % usable, 3.6 m10 t/h, 20 min, 1.2 bar(a), 75 %, no diameter

Enter your specification's storage time. Default from FireCAD design practice; enter your specification's value.
The water is taken as saturated at this pressure.
Volume between normal water level and low-low level divided by the total volume. Enter your design's value.

Results

Total tank volume12.717m³
Storage (working) volume8.9018m³
Length of a horizontal cylinder of that diameter2.8110m
Water density at saturation954.87kg/m³

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 50 t/h, 10 min, deaerator 1.2 bar(a), 70 % usable, 2.4 m diameter. The inputs, in the units selected above:

InputValue
Feed water flow (boiler MCR plus blowdown)51,000 kg/h
Storage time between normal and low-low level10.000 min
Deaerator pressure (absolute)1.2000 bar
Usable share of the tank volume70.000 %
Tank inside diameter for the length (0 = skip)2.4000 m

Applying the formula below gives:

ResultValue
Total tank volume12.717 m³
Storage (working) volume8.9018 m³
Length of a horizontal cylinder of that diameter2.8110 m
Water density at saturation954.87 kg/m³

Open this example in the calculator and change any input.

Formula

\(V_s = \frac{\dot m_{fw}\,t_s}{\rho} \qquad V_t = \frac{V_s}{f} \qquad L = \frac{V_t}{\pi D^2/4}\)

Variables

Symbol Meaning SI unit
\(\dot m_{fw}\) feed water flow kg/s
\(t_s\) storage time between normal and low-low level s
\(p_{da}\) deaerator pressure, absolute Pa
\(f\) usable share of the tank volume –
\(D\) tank inside diameter m
\(V_t\) total tank volume m³
\(V_s\) storage volume m³
\(L\) length of a horizontal cylinder of that diameter m
\(\rho\) density of saturated water at \(p_{da}\) kg/m³

Method and standards

Volume balance; density of saturated water at the deaerator pressure from FireCAD's IAPWS-IF97.

Where it is used

  • Sizing feed tanks and deaerator storage.
  • Checking holding time after a boiler uprating.
  • Setting low-level alarms and trips.

Common mistakes

  • Counting the whole tank volume instead of the usable volume between levels.
  • Using cold-water density for hot feedwater.
  • Ignoring condensate surges on start-up.

Assumptions and limits

  • The length is that of a plain cylinder; dished ends add volume (use the tank volume calculator for the ends).
  • The usable share depends on the level settings and the tank shape; for a horizontal tank it is not the same as the height ratio.

References

  • IAPWS R7-97(2012) IF97 (saturated water density)

Questions and answers

How big should a deaerator storage tank be?

Volume = feed flow × storage time ÷ water density ÷ usable share. For 51 t/h with 10 minutes of storage at 1.2 bar(a), the working volume is 8.9 m³ and, with 70 % of the tank usable, the tank holds 12.7 m³.

What storage time should I use?

The one your specification gives; it depends on how long the plant needs to ride through a loss of make-up or condensate. The calculator does not suggest a value.

Why is the density below 1 000 kg/m³?

Deaerated water is at its boiling point: 955 kg/m³ at 1.2 bar(a) (105 °C) and 909 kg/m³ at 6 bar(a).

Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.