Worked example
Example: 50 t/h, 10 min, deaerator 1.2 bar(a), 70 % usable, 2.4 m diameter. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Feed water flow (boiler MCR plus blowdown) | 51,000 kg/h |
| Storage time between normal and low-low level | 10.000 min |
| Deaerator pressure (absolute) | 1.2000 bar |
| Usable share of the tank volume | 70.000 % |
| Tank inside diameter for the length (0 = skip) | 2.4000 m |
Applying the formula below gives:
| Result | Value |
|---|---|
| Total tank volume | 12.717 m³ |
| Storage (working) volume | 8.9018 m³ |
| Length of a horizontal cylinder of that diameter | 2.8110 m |
| Water density at saturation | 954.87 kg/m³ |
Open this example in the calculator and change any input.
Formula
\(V_s = \frac{\dot m_{fw}\,t_s}{\rho} \qquad V_t = \frac{V_s}{f} \qquad L = \frac{V_t}{\pi D^2/4}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_{fw}\) | feed water flow | kg/s |
| \(t_s\) | storage time between normal and low-low level | s |
| \(p_{da}\) | deaerator pressure, absolute | Pa |
| \(f\) | usable share of the tank volume | – |
| \(D\) | tank inside diameter | m |
| \(V_t\) | total tank volume | m³ |
| \(V_s\) | storage volume | m³ |
| \(L\) | length of a horizontal cylinder of that diameter | m |
| \(\rho\) | density of saturated water at \(p_{da}\) | kg/m³ |
Method and standards
Volume balance; density of saturated water at the deaerator pressure from FireCAD's IAPWS-IF97.
Where it is used
- Sizing feed tanks and deaerator storage.
- Checking holding time after a boiler uprating.
- Setting low-level alarms and trips.
Common mistakes
- Counting the whole tank volume instead of the usable volume between levels.
- Using cold-water density for hot feedwater.
- Ignoring condensate surges on start-up.
Assumptions and limits
- The length is that of a plain cylinder; dished ends add volume (use the tank volume calculator for the ends).
- The usable share depends on the level settings and the tank shape; for a horizontal tank it is not the same as the height ratio.
References
- IAPWS R7-97(2012) IF97 (saturated water density)
Questions and answers
How big should a deaerator storage tank be?
Volume = feed flow × storage time ÷ water density ÷ usable share. For 51 t/h with 10 minutes of storage at 1.2 bar(a), the working volume is 8.9 m³ and, with 70 % of the tank usable, the tank holds 12.7 m³.
What storage time should I use?
The one your specification gives; it depends on how long the plant needs to ride through a loss of make-up or condensate. The calculator does not suggest a value.
Why is the density below 1 000 kg/m³?
Deaerated water is at its boiling point: 955 kg/m³ at 1.2 bar(a) (105 °C) and 909 kg/m³ at 6 bar(a).
Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.