FireCADCalc

Exergy of Steam and of Heat at a Temperature (IAPWS-IF97)

Specific and flow exergy of steam or water at a pressure and temperature relative to a dead state, and the exergy of a heat flow at a temperature (Carnot factor).

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolRefinery and petrochemicalChemical and fertiliserIAPWS-IF97 (water and steam)

Inputs

Examples: 10 bar 250 °C, 10 t/h, 25 °C dead state40 bar 400 °CHot water 5 bar 120 °C

Results

Exergy is the maximum work obtainable by bringing the stream to the dead state; its destruction marks where a plant loses useful energy.

Enthalpy2,943.2kJ/kg
Entropy6.9266kJ/(kg·K)
Specific exergy882.61kJ/kg
Exergy flow of the steam2,451.7kW
Exergy share of the energy above the dead state31.097%
Exergy of the heat flow295.40kW

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 10 bar 250 °C, 10 t/h, 25 °C dead state. The inputs, in the units selected above:

InputValue
Steam pressure (absolute)10.000 bar
Steam temperature250.00 °C
Steam flow10.000 t/h
Dead-state (ambient) temperature25.000 °C
Dead-state pressure (absolute)101.33 kPa
Heat flow (for the heat exergy)1,000.0 kW
Temperature at which the heat is available150.00 °C

Applying the formula below gives:

ResultValue
Enthalpy2,943.2 kJ/kg
Entropy6.9266 kJ/(kg·K)
Specific exergy882.61 kJ/kg
Exergy flow of the steam2,451.7 kW
Exergy share of the energy above the dead state31.097 %
Exergy of the heat flow295.40 kW

Open this example in the calculator and change any input.

Formula

\(e = (h - h_0) - T_0(s - s_0), \quad \dot E = \dot me, \quad \dot E_Q = Q\left(1 - \frac{T_0}{T_Q}\right)\)

Variables

Symbol Meaning SI unit
\(p\) Steam pressure (absolute) Pa
\(T\) Steam temperature K
\(\dot m\) Steam flow kg/s
\(T_0\) Dead-state (ambient) temperature K
\(p_0\) Dead-state pressure Pa
\(Q\) Heat flow (for the heat exergy) W
\(T_Q\) Temperature at which the heat is available K
\(h\) Enthalpy J/kg
\(s\) Entropy J/(kg·K)
\(e\) Specific exergy J/kg
\(\dot E\) Exergy flow of the steam W
\(e/(h - h_0)\) Exergy share of the energy above the dead state -
\(\dot E_Q\) Exergy of the heat flow W

Method and standards

Exergy definitions with IAPWS-IF97 properties.

Where it is used

  • Comparing steam levels and letdown losses.
  • Second-law efficiency of boilers, turbines and heat recovery.

Common mistakes

  • Using a dead state that is not ambient.
  • Comparing energy and exergy efficiencies as if they were the same.

Assumptions and limits

  • Physical exergy only; kinetic and chemical exergy excluded.
  • The exergy share is shown as 0 when the stream is at the dead-state enthalpy; below it (cold water) the share is not meaningful and a note appears.
  • The dead state must be liquid water: T_0 below the saturation temperature at p_0.
  • Heat at a temperature below ambient (T_Q < T_0) gives a negative exergy of heat: the exergy flows opposite to the heat, as in refrigeration.

References

  • IAPWS-IF97 (FireCAD engine); exergy e = h − h₀ − T₀(s − s₀) and E_Q = Q(1 − T₀/T) (Bejan, Tsatsaronis and Moran, Thermal Design and Optimization, Wiley, 1996)

Questions and answers

Why is exergy useful?

It shows the quality of energy: 1 MW of 10 bar steam can do far more work than 1 MW of warm water, and exergy measures that.

What do the defaults give?

10 bar, 250 °C steam against 25 °C: about 900 kJ/kg of exergy, roughly a third of its enthalpy above the dead state.

What dead state should I use?

The local ambient air or cooling-water temperature and atmospheric pressure.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.