Worked example
Example: 10 bar 250 °C, 10 t/h, 25 °C dead state. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Steam pressure (absolute) | 10.000 bar |
| Steam temperature | 250.00 °C |
| Steam flow | 10.000 t/h |
| Dead-state (ambient) temperature | 25.000 °C |
| Dead-state pressure (absolute) | 101.33 kPa |
| Heat flow (for the heat exergy) | 1,000.0 kW |
| Temperature at which the heat is available | 150.00 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Enthalpy | 2,943.2 kJ/kg |
| Entropy | 6.9266 kJ/(kg·K) |
| Specific exergy | 882.61 kJ/kg |
| Exergy flow of the steam | 2,451.7 kW |
| Exergy share of the energy above the dead state | 31.097 % |
| Exergy of the heat flow | 295.40 kW |
Open this example in the calculator and change any input.
Formula
\(e = (h - h_0) - T_0(s - s_0), \quad \dot E = \dot me, \quad \dot E_Q = Q\left(1 - \frac{T_0}{T_Q}\right)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(p\) | Steam pressure (absolute) | Pa |
| \(T\) | Steam temperature | K |
| \(\dot m\) | Steam flow | kg/s |
| \(T_0\) | Dead-state (ambient) temperature | K |
| \(p_0\) | Dead-state pressure | Pa |
| \(Q\) | Heat flow (for the heat exergy) | W |
| \(T_Q\) | Temperature at which the heat is available | K |
| \(h\) | Enthalpy | J/kg |
| \(s\) | Entropy | J/(kg·K) |
| \(e\) | Specific exergy | J/kg |
| \(\dot E\) | Exergy flow of the steam | W |
| \(e/(h - h_0)\) | Exergy share of the energy above the dead state | - |
| \(\dot E_Q\) | Exergy of the heat flow | W |
Method and standards
Exergy definitions with IAPWS-IF97 properties.
Where it is used
- Comparing steam levels and letdown losses.
- Second-law efficiency of boilers, turbines and heat recovery.
Common mistakes
- Using a dead state that is not ambient.
- Comparing energy and exergy efficiencies as if they were the same.
Assumptions and limits
- Physical exergy only; kinetic and chemical exergy excluded.
- The exergy share is shown as 0 when the stream is at the dead-state enthalpy; below it (cold water) the share is not meaningful and a note appears.
- The dead state must be liquid water: T_0 below the saturation temperature at p_0.
- Heat at a temperature below ambient (T_Q < T_0) gives a negative exergy of heat: the exergy flows opposite to the heat, as in refrigeration.
References
- IAPWS-IF97 (FireCAD engine); exergy e = h − h₀ − T₀(s − s₀) and E_Q = Q(1 − T₀/T) (Bejan, Tsatsaronis and Moran, Thermal Design and Optimization, Wiley, 1996)
Questions and answers
Why is exergy useful?
It shows the quality of energy: 1 MW of 10 bar steam can do far more work than 1 MW of warm water, and exergy measures that.
What do the defaults give?
10 bar, 250 °C steam against 25 °C: about 900 kJ/kg of exergy, roughly a third of its enthalpy above the dead state.
What dead state should I use?
The local ambient air or cooling-water temperature and atmospheric pressure.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.