FireCADCalc

Direct Steam Injection Heating (Steam Required)

Steam needed to heat water or a process liquid by direct injection (sparging), where the steam condenses into the liquid, from flow and temperatures (IAPWS-IF97).

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationPulp and paperFood, dairy and textileIAPWS-IF97 (water and steam)Boiler

Inputs

Examples: Water 5 kg/s from 20 to 80 °C, steam 6 bar(a)Sugar juice 20 kg/s, 60 to 100 °C, 3 bar(a), c_p 3.9 kJ/(kg K)Hot water 1 kg/s, 15 to 60 °C, 8 bar(a)

Results

All the steam condenses and stays in the product, which is diluted; the steam must be clean (culinary) where the product is food.

Steam needed4,871.5kg/h
Steam per kg of liquid0.067660kg/kg
Liquid flow out (diluted by condensate)76,872kg/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Water 5 kg/s from 20 to 80 °C, steam 6 bar(a). The inputs, in the units selected above:

InputValue
Liquid flow to heat18,000 kg/h
Specific heat of the liquid4.1800 kJ/(kg·K)
Liquid temperature in20.000 °C
Liquid temperature out80.000 °C
Steam pressure (absolute, saturated)6.0000 bar

Applying the formula below gives:

ResultValue
Steam needed1,864.9 kg/h
Steam per kg of liquid0.10360 kg/kg
Liquid flow out (diluted by condensate)19,865 kg/h

Open this example in the calculator and change any input.

Formula

\(\dot m_s = \frac{\dot m\,c_p\,(T_2 - T_1)}{h_g - h_l(T_2)} \qquad \dot m_2 = \dot m + \dot m_s\)

Variables

Symbol Meaning SI unit
\(\dot m\) liquid flow kg/s
\(c_p\) liquid specific heat J/(kg·K)
\(T_1\) liquid in K
\(T_2\) liquid out K
\(p_s\) steam pressure Pa
\(\dot m_s\) steam needed kg/s
\(\dot m_s/\dot m\) steam per kg of liquid kg/kg
\(\dot m_2\) liquid out kg/s
\(h_g\) saturated steam enthalpy (IF97) J/kg
\(h_l\) enthalpy of the condensate at T₂, taken at the steam pressure (IF97) J/kg

Method and standards

Energy balance with the steam condensing completely and leaving at the outlet temperature.

Where it is used

  • Hot water generation, CIP and process water heating.
  • Cooking, starch and pulp heating.
  • Comparing direct and indirect heating.

Common mistakes

  • Forgetting dilution of the product.
  • Injecting too much steam at once (hammer, uncondensed steam).
  • Counting the condensate as returned make-up.

Assumptions and limits

  • Complete condensation; no heat loss; saturated steam.
  • The condensate enthalpy is taken at the steam pressure; for liquid water its pressure hardly matters.
  • Above about 100 °C the product must be pressurised so it does not boil; the liquid pressure is not an input, and a warning appears.
  • The steam-to-liquid ratio is shown even for zero flow.

References

  • Energy balance
  • IAPWS R7-97 IF97

Questions and answers

How much steam heats water by injection?

5 kg/s of water from 20 to 80 °C with 6 bar(a) steam needs 0.52 kg/s (1865 kg/h), about 10 % of the water flow.

Why less steam than indirect heating?

All the steam's heat stays in the liquid, including the condensate's own heat; with a coil the condensate leaves hot.

What are the drawbacks?

The product is diluted by the condensate, the steam must be clean, and the condensate is not returned to the boiler.

Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.